BRAHM TM BC Central Collector Series
P OWER D ISCONNECT S WITCH
This switch controls the main power to the BRAHM™ Collector.
When the switch is in the “0” or “OFF” position, the main power to the unit is disconnected. When in the “1” or “ON” position, main power is reaching the unit and it can be started. Under normal operating conditions, the unit will not
start when the green "START" push button is depressed if the Disconnect is in the "0" or "OFF" position. This switch also provides a means to lock out the switch using a small padlock thus preventing accidental power up. This is an interlocking disconnect; meaning, the door to the electrical box will not open if the switch is in the "ON" position. When dial is in: “0” position — all main power to the unit is OFF “1” position — the unit is powered up and ready for operation, the unit is ON CAUTION:
Prior to performing maintenance always use a meter to confirm the power source is locked out.
sales@clean-air.com
clean-air.com
1-866-665-1829
Made with FlippingBook Online newsletter maker