S HUTDOWN PROCEDURES
Proper BRAHM™ Collector shutdown is one of the key factors to achieving maximum filter cartridge life. To properly shutdown the BRAHM™ Collector, simply depress the red “STOP” button. If the BRAHM™ Collector has reached a high enough pressure drop, the unit will begin to cycle through its offline cleaning process. If the default settings are being used, this will take about 3 to 14 minutes depending on the unit. Always wait for the offline cleaning process to finish before disengaging the Power Disconnect switch. The blower will not stop immediately, and may take several minutes to fully stop. The automatic cleaning system will continue to operate even if the red "STOP" button has been depressed. This is normal and desirable; the offline cleaning is the most efficient cleaning method. Do NOT use the Power Disconnect switch to deactivate the unit unless it is an emergency situation.
NOTE:
Do NOT shut down the Brahm™ Collector by disengaging the Power Disconnect. If the Brahm™ Collector is shut down in this manner, it will NOT perform offline cleaning and will diminish the life of the filter cartridges.