C ARTRIDGE F ILTER M AINTENANCE Filter Features

Filter Design: #1834 Filter Dimensions: 12.75" OD x 26" Long 80/20 polyester, fire retardant

Pleat Construction Flame Retardant 226 sq. ft. per filter Standard Operating Temperature up to 220° F Short Time Exposure up to 300° F Mullen burst rated at 25 psig Other Filters are available depending on the application. Filter Maintenance Filters are of excellent construction and of the best quality available. The filters are preconditioned with a unique process which has proven to be effective over time with long filter life and

excellent cleaning characteristics. The cellulose media is even able to withstand and recover from water immersion due to the filter’s high resin content (22% by weight) and mechanical resilience. It is important to keep the filters clean and replaced on the proper interval for the proper operation of the BRAHM™ Collector. The point when the filters must be changed depends upon the specific application. Welding, cutting, and grinding frequency, the type of particulate that is being removed, the type of filters being used, part cleanliness, and the type of welding being performed all effect the filter replacement interval. Because of all of these factors, the customer must monitor and document the system airflow readings for a period of time. The information collected will help determine the most appropriate time to change filters. This process will ensure that the system runs at maximum efficiency while minimizing filter replacement costs.