Power Start / Stop Switch
This switch is NOT present on HMI based units. The starting and stopping functions are built into and must be operated from the HMI touch Screen the HMI touch Screen. This switch controls the operation of the motor / blower. The green “START” button begins the unit operation. The red “STOP” button stops the unit operation The center light will illuminate when the “Start” button is depressed. The light will remain illuminated until the “Stop” button is depressed.
The optional remote start / stop switch can be installed to control operation of the motor / blower from a second location. The unit can be started or stopped from either location.
The optional Clean Air Economizer TM switch can be installed to control operation of the motor / blower based on usage. The panel mounted switch will illuminate normally. The unit can be started from either location; however, the unit can only be stopped by pressing the red "STOP" button. The economizer will not activate unless the green start button has been pressed at least once since the last power activation.