C OMPRESSED A IR C ONNECTION

In order for the automatic pulse filter cleaning system to operate, the Clean Air Industries Liberty Weldcell requires a compressed air connection to be made.

The compressed air inlet is located at the back of the unit

This Liberty Weldcell compressed air inlet supply is a 1” NPT male fitting

Use a regulator to adjust the pressure to 70 to 90 PSI.

A dryer may be needed to condition the air before entering the Liberty Weldcell.

1.0 ft 3 Valve Pulse at 70 - 90 psi

5/8" Minimum compressed air supply line required; 1" Recommended

NOTE: Do not operate the Liberty Weldcell for an extended period of time without an

appropriate compressed

air supply. Doing so will

greatly diminish the life

of the filter cartridges.

A IR R EGULATOR

The compressed air for the Liberty

Weldcell must be regulated at 70 to 90

PSI. A Regulator is used to allow the

high-pressure air supply lines or tanks

to be reduced to safe and usable

pressure for pulsing the unit. If the pressure is too low, the valves may not properly clean the filters. If

the pressure is too high, it may damage the valves.

A IR F ILTER

The compressed air for the Liberty Weldcell must be clean. Dirty air entering the system can cause

damage to pneumatic components. The air should be filtered to remove all contaminants by the

compressed air supply system prior to entering the Liberty Weldcell.