Liberty Weld Cell User & Maintenance Manual

Fire Pull

The fire pull is used for the manual activation of the fire suppression system. These are typically

mounted remotely so that cell operators can activate them in emergency

situations. The fire pull will be mounted on the front of the electrical door. A

key is used to reset the fire pull once it has been activated, and a glass

tube can be inserted to detect an activation that has been reset.

To reset the fire pull, the power must be turned off before the fire pull has

been reset. The internal program of the Smart Relay latches shut

electronically, forcing the power to be cycled off and then on. If the fire pull

has been activated, the Fire Pull Indicator will light up as shown in the

picture below. This will then engage the fire pull action (see Fire

Suppression Function section for more details)