Liberty Weld Cell User & Maintenance Manual

C ARTRIDGE F ILTER M AINTENANCE

Filter Features

Filter Dimensions: 19.7" OD x 26" Long

100% Cellulose, 22% Resin by Weight

Pleat Construction

Flame Retardant

(1) Filter for a total area of 320 sq. ft.

Standard Operating Temperature up to 220° F

Short Time Exposure up to 300° F

Mullen burst rated at 25 psig

Other Filters are available depending on the application.

Filter Maintenance

Filters are of excellent construction and of the best quality

available. The filters are preconditioned with a unique process

which has proven to be effective over time with long filter life and

excellent cleaning characteristics. The cellulose media is even

able to withstand and recover from water immersion due to the

filter’s high resin content (22% by weight) and mechanical resilience.

It is important to keep the filters clean and replaced on the proper interval for the proper operation of

the Liberty Weldcell. The point when the filters must be changed depends upon the specific

application. Welding and grinding frequency, the type of particulate that is being removed, the type of

filters being used, and the type of welding being performed all effect the filter replacement interval.

Because of all of these factors, the customer must monitor and document the system airflow readings

for a period of time. The information collected will help determine the most appropriate time to change

filters. This process will ensure that the system runs at maximum efficiency while minimizing filter

replacement costs.

The easy access system of the Liberty Weldcell helps with faster filter replacement and reduced

maintenance.

Copyright © Clean Air Industries , Inc.

Liberty WeldCell User Manual, August 2023