Liberty Weld Cell User & Maintenance Manual

How to replace filters

NOTE: It is important to ensure that the filter gaskets seal correctly for proper operation of

the Liberty Weldcell. This will ensure that you do not get particulate past the filter

compartment. The easy filter clamping system of the Liberty Weldcell helps with

faster filter replacement and maintenance.

1) Press the red 'STOP' double push button and

allow blower to spin down. This may take

several minutes.

2) Rotate the Disconnect Switch / Emergency

Stop Switch to the '0' or 'OFF' position. This

will disconnect power to the unit to prevent

the unit from being started during the filter

change. Please follow all lock out - tag out

procedures.

3) Shut off the compressed air supply to the

Liberty Weldcell.

4) Open the filter door to allow access to the

filter compartment and reveal the cartridge

filters.

5) When the filter door is opened, you will

notice a large handle on your left side of the

filter.

6)

Grab the bottom of the handle and pull it

towards you, and up. This will loosen the

filter(s).

7) Once the filter clamp has been loosened,

locate and remove the filter caps. The filter

caps are round black plates, located on top

of each filter stack.

8) Once the filter caps have been removed, the

filter can be accessed.

Copyright © Clean Air Industries , Inc.