The air supply to the Streamer must be dry or drained. Water carried with air into the Streamer can
wash away lubricating oil. This can mean excessive wear to pneumatic components and higher
maintenance expenses. Without adequate lubrication pneumatic components can run sluggishly and
inefficiently be prone to air leakage. Water in the supply line must be removed using a dryer or water
drain trap.
S HUT O FF V ALVE
Each unit must be fitted with a shut off valve capable of being locked out with blow off capability.
Safety procedures such as lock out / tag out procedures must be followed with pneumatic as well as
electrical systems. This means, the valve must be a 2-way valve which will exhaust the air from the
Streamer when the shut off valve has been locked out. The exhaust port should be fitted with a
pneumatic muffler to reduce noise if above unacceptable levels.
Copyright © Clean Air America, Inc.
Streamer User Manual, March 2015
Page 22 of 54