E LECTRICAL CONNECTIONS
Clean Air America Streamers can be set up
to operate on various power sources. Please
see the following electrical chart based on the
specified power. To ensure proper operation,
a certified Clean Air America, Inc. installer or
professional electrician should perform power
connections. Any damage incurred from
improper electrical power connection will void
the warranty of the Streamer.
The incoming power is connected to the unit
at the conduit connection located on the top
of the unit in front of the exhaust panel. For
convenience and quick connection, there is a
3/4" Weather tight female EMT fitting. The
EMT fitting can be remove leave a female
Rigid Metal Conduit (RMC) connection.
When power is brought into the
Streamer through the EMT Conduit
fitting, it will enter the electrical box at
the top of the box.
First make the ground connection into
the grounding terminal block.
The incoming power wires must be
terminated on the incoming side of
the power disconnect switch /
emergency shut off switch (L1, L2,
L3).