P OWER D ISCONNECT S WITCH / E MERGENCY S HUT O FF S WITCH
This switch controls the main power to the Streamer.
When the switch is in the “0” or "OFF"
position, the main power to the unit is
disconnected.
When in the “1” or "ON" position, main
power is reaching the unit and it can be
started.
Under normal operating conditions, the unit
will not start when the green "START" push
button is depressed if the disconnect is in
the "0" or "OFF" position.
This switch also provides a means to lock out the switch using a small padlock thus
preventing accidental power up.
This is an interlocking disconnect; meaning, the door to the electrical box will not open if the
switch is in the "ON" position.
When dial is in:
“0” position — all main power to the unit is OFF
“1” position — the unit is powered up and ready for operation, the unit is ON
CAUTION:
Prior to performing maintenance always use a meter to confirm the
power source is locked out.
Copyright © Clean Air America, Inc.
Streamer User Manual, March 2015
Page 25 of 54