Clean Air America Push-Pull Streamer Series User Manual

S TARTUP P ROCEDURES

The Streamer power must first be turned on by rotating the Power Disconnect / Emergency

Shut Off switch to the 'ON' position.

The unit can then be started by simply depressing the green "RUN" button.

The blower will start immediately, but may take a minute or two to reach full speed.

The automatic pulse cleaning system will automatically turn on in the automatic mode.

S HUTDOWN PROCEDURES

Proper Streamer shutdown is one of the key factors to achieving maximum filter cartridge life. To

properly shutdown the Streamer , simply depress the red “Stop” button. After approximately 1 minute,

the Streamer will begin to cycle through its offline cleaning process. If the default settings are being

used, this will take about 3 to 4 minutes. However, if the default settings are not being used, this off

line cleaning cycle could take upwards of 10 minutes. Always wait for the offline cleaning process to

finish before disengaging the Power Disconnect / Emergency Shut Off switch.

The Streamer can be shutdown easily by simply depressing the red “STOP” button.

The blower will not stop immediately, and may take several minutes to fully stop.

The automatic cleaning system will continue to operate even if the red "STOP" button has

been depressed. This is normal and desirable; the off line cleaning is the most efficient

cleaning method.

Do NOT use the Power Disconnect / Emergency Shut Off switch to deactivate the unit

unless it is an emergency situation.

NOTE:

Do NOT shut down the Streamer by disengaging the Power Disconnect /

Emergency Shut Off unless it is an emergency situation. If the Streamer is

shut down in this manner, it will NOT perform offline cleaning and will

diminish the life of the filter cartridges.

Copyright © Clean Air America, Inc.

Streamer User Manual, March 2015

Page 35 of 54