Reliable values SoloCem oers excellent adhesion and reliable, long-lasting bonding to dentin, enamel and other materials.
Shear bond strength according to the Ultradent*-method (dual cured)
Shear bond strength according to the Ultradent*-method (chemically cured)
SoloCem
Titanium
Ceramic, feldspar ceramic, TriLuxe for Cerec® *
Rely X Unicem2 Automix *
Maxcem Elite *
Gold
0
2
4
6
8
10
12
Cobalt/Chromium
MPa
0
5 1015202530
MPa
Enamel (cut)
Dentin
Source: internal data
Source: internal data
Next to good adhesion values, low shrinkage also determines the quality of a bond, which in turn has a positive eect on the durability of restorations.
The REM image below demonstrates the excellent bonding between endodontic posts, SoloCem and dentin.
Shrinkage
Post
SoloCem
Rely X Unicem2 Automix *
SoloCem
Dentin
Maxcem Elite *
0
1
2
3
4
5
6
7
%
Source: internal data
Source: internal data
Clinical times
Technical data
Composition
working time
■■ Flexural strength 115 MPa ■■ Compressive strength 190 MPa ■■ Radiopacity 4 mm Al / mm
■■ Methacrylates ■ Zinc oxide ■■ Dental glass
120 s
23°C 37°C
60 s
curing time (not including working time)
180 s
Storage
37°C
* Not a registered trademark of Coltène/Whaledent
Source: internal data
Made with FlippingBook flipbook maker