Fluke Australia 2020 Test Tools Catalogue

Fluke Calibration 9142, 9143 and 9144 Field Metrology Wells

Recommended Accessories

Field temperature calibration with precision and speed Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Fluke Calibration Field Metrology Well is the right tool for the job. With three models covering the range of –25 °C to 660 °C, this family of Metrology Wells calibrates a wide range of sensor types. The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter. • Lightweight, portable, and fast • 9142 –25 °C to 150 °C ± 0.2 °C • 9143 33 °C to 350 °C ± 0.2 °C • 9144 50 °C to 660 °C ± 0.35 °C to 420 °C ± 0.5 °C at 660 °C • Cool to –25 °C in 15 minutes and heat to 660 °C in 15 minutes • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current • True reference thermometry with accuracy to ±0.01 °C • Automate calibration with the Fluke 754 or Fluke 1586A or use on-board automation with process version • One year warranty

HART DRYWELL CABLE 754/Dry-Well/Microbath Interface Cable

9142-CASE Carrying Case (914X)

Fluke 9308/9316

Fluke 9144

9308 Carrying Case

9316 Rugged Carrying Case

Complete Solution Fluke 754 with 914X Series Field Metrology Well By combining the automating and documenting capabilities of the Fluke 754 Documenting Process Calibrator (see page 109) with Fluke Calibration’s intelligent and stable family of field drywells and micro-baths, you have the capability to test the entire loop. This combination of equipment allows you to easily verify the characteristics of the temperature sensor and measurement electronics. Using this information, the entire loop can be adjusted to optimise system measurement performance.

Well inserts X in the model number to be replaced with A, B, C, D, E, or F as appropriate for the desired insert.

Models

9142-X Field MetrologyWell, -25 °C to 150 °C 9142-INSA 9142-INSB 9142-INSC 9142-X-P Field MetrologyWell, -25 °C to 150 °C, process version 9143-X Field MetrologyWell, 33 °C to 350 °C 9143-INSA 9143-X-P Field MetrologyWell, 33 °C to 350 °C, process version 9144-X Field MetrologyWell, 50 °C to 660 °C 9144-INSA 9143-INSB 9143-INSC

Insert A, 9142, misc holes Insert B, 9142, comp holes Insert C, 9142, 6 x 0.25 in holes Insert A, 9143, misc holes Insert B, 9143, comp holes Insert C, 9143, 6 x 0.25 in holes Insert A, 9144, misc holes Insert B, 9144, comp holes Insert C, 9144, 6 x 0.25 in holes

9144-INSB 9144-INSC

9144-X-P Field MetrologyWell, 50 °C to 660 °C, process version

Fluke Calibration 9103 and 9140 Field Dry-Well Calibrators

Fluke Calibration's 9103 and 9140 Field Dry-Well Calibrators beat every other comparable dry-well in the industry in performance, size, weight, convenience, ease of calibration, software, and price. In addition, the heating and cooling rate of each of these dry-wells is adjustable from the front panel, thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes. • Lightweight and very portable • Two models ranging from -25 °C to 350 °C

• Accuracy to ± 0.25 °C • Stability to ± 0.02 °C • RS-232 and Interface-it software included

• Easy to recalibrate • One year warranty

Fluke 9140

Specify X, X = A, B, C, or D included insert Insert A: 1/16” (1.6 mm), 1/8” (3.2 mm), 3/16” (4.8 mm), 1/4” (6.35 mm), 3/8” (9.5 mm) & 1/2” (12.7 mm) Insert B: 2 at 3/16” (4.8 mm), 2 at 1/4” (6.35 mm) & 2 at 3/8” (9.5 mm) Insert C: 6 at 1/4” (6.35 mm) Insert D: 2 at 3mm, 2 at 4 mm & 2 at 6 mm

Models

9103-X Field Dry-Well Calibrator, –25 °C to 140 °C 9140-X Field Dry-Well Calibrator, 35 °C to 350 °C

For more information, go to http://au.flukecal.com

www.fluke.com/au/PCT