Fluke Australia 2020 Test Tools Catalogue

Fluke Calibration 9132/9133 Portable Infrared Calibrator

Recommended Accessories

Precision when you need it for infrared temperature calibration Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C. These units feature a temperature controlled measurement surface with a diameter of 57 mm. The target temperature can be controlled in set-point increments of 0.1 ° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact calibration. • Certify IR pyrometers from –30 °C to 500 °C • Large 57 mm blackbody target • RTD reference well for contact temperature measurement • Small, compact design • One year warranty

9308 Carrying Case

9302 Carrying Case

Fluke 9132

4180-APRT 2” Aperture, (4180 or 4181)

4180-CASE Carrying Case, (4180 or 4181)

Fluke 9133

General Specifications

9132

9133

Temperature Range

50°C to 500°C ±0.5°C at 100°C ±0.8°C at 500°C

–30°C to 150°C at 23°C ambient

Accuracy

±0.4°C

Target Size

57 mm

57 mm

Target Emissivity

0.95 (±0.02 from 8 to 14 mm) 30 minutes (50°C to 500°C) 30 minutes (500°C to 100°C)

0.95 (±0.02 from 8 to 14 mm) 15 minutes (25°C to 150°C) 15 minutes (25°C to –20°C)

Heating Time Cooling Time

Fluke Calibration 4180/4181 Precision Infrared Calibrators

Accredited performance for point and shoot calibrations Now it’s easy to increase your IR temperature measurement accuracy with the 4180 and 4181 Precision Infrared Calibrators. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimises size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings. • Calibrated radiometrically for meaningful, consistent results • Accurate, reliable performance from –15 °C to 500 °C • Large target size of 152 mm is required for calibrating most thermometers • Accredited radiometric calibration report • One year warranty

Ordering Information

Fluke 4180

9312-256

Portable IR Calibrator 50°C to 500°C Portable IR Calibrator -30°C to 150°C

9133-256

4180

Precision Infrared Calibrator, –15 °C to 120 °C Precision Infrared Calibrator, 35 °C to 500 °C

4181

For more information, go to http://au.flukecal.com

www.fluke.com/au/PCT

Process Calibration Tools

115

Made with FlippingBook Learn more on our blog