Fluke Australia 2020 Test Tools Catalogue

Fluke 77IV Digital Multimeter

Recommended Accessories

Versatile multimeter for field service or bench repair The Fluke 77IV Digital Multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that is easier to view. • Wide 1000 V measurement range • Average responding AC measurements • 0.3 % accuracy • 10 amps continuous

I400

C35

AC Current Clamp See page 148

Soft Carrying Case See page 152

• Frequency and capacitance • Resistance and continuity • Large display • Backlight for work in dim areas

TPAK Magnetic

TL225

SureGrip™ Stray Voltage Adapter Test Lead Kit See page 144

• Min/Max to record signal fluctuations • Integral holster with probe holders • Free your hands with the optional TPAK magnetic hanger • Auto and manual ranging • Battery Life: 400 hours typical • Weight: 0.42 kg

Meter Hanger See page 154

Fluke 77IV

• Size (HxWxD): 185 mm x 90 mm x 43 mm • Limited lifetime manufacturer's warranty

I2000 FLEX AC Current Clamp See page 148

TLK-225

SureGrip ™ Master Accessory Kit See page 144

Function Voltage DC Voltage AC Current DC Current AC Resistance Capacitance Frequency

Maximum

Max. resolution

Accuracy ±(0.3%+1) ±(2.0%+2) ±(1.5%+2) ±(2.5%+2) ±(0.5%+1) ±(1.2%+2) ±(0.1%+1)

1000 V 1000 V

1 mV 1 mV

10 A 10 A

0.01 mA 0.01 mA

50 MΩ

0.1 Ω 1 nF

9,999 μF 99.99 kHz

0.01 Hz

Accuracies are best accuracies for each function.

General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Counts ]).

Specifications

77IV

V Maximum voltage between any terminal and earth ground

1000 V

Surge protection

8 kV peak per IEC 61010 440 mA, 1000 V FAST Fuse 11 A, 1000 V FAST Fuse

W Fuse for mA input W Fuse for A input

Display

Digital: 6,000 counts, updates 4/sec

Bar Graph Frequency Capacitance

33 segments, updates 32/sec

10,000 counts 1,000 counts 2,000 metres 12,000 metres

Operating altitude Storage altitude

Operating temperature Storage temperature Temperature coefficient

-10 °C to + 50 °C -40 °C to + 60 °C

0.1 X (specified accuracy/°C (< 18 °C or > 28 °C) In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accu- racy ± 5 °C 90 % to 35 °C; 75 % to 40 °C; 45 % to 50 °C

Included Accessories Test Leads with 4mm Lantern Tips, 9V Battery (installed), Manual Information Pack.

Electromagnetic compatibility (EN 61326-1:1997)

Relative humidity (maximum non-condensing)

Ordering Information

Battery life

400 hours

FLUKE-77-4

Digital Multimeter

Size (HxWxL) and Weight

185mm x 90mm x 43mm; 420 grams

Safety compliance

ANSI/ISA S82.02.01, CSA C22.2-1010.1, IE 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV CSA, TÜV (EN61010), UL, ∏, (N10140), VDE

C ontact your local distributor for price and availability. www.fluke.com/au/wtb

Certifications

www.fluke.com/au/dmm

Digital Multimeters

23

Made with FlippingBook Learn more on our blog