Fluke 370 Series Clamp Meters
Be ready for anything The Fluke 370 Series of True-RMS Clamp Meters provides a range of state of-the-art features to meet even the most demanding job requirements. All four of the clamp meters have improved base features such as a large, backlit display, true- RMS standard, CAT IV safety rating and a durably constructed body. Additionally, the 376 FC, 375 FC and 374 FC are a part of the Fluke Connect ® family of wireless test tools and are compatible with the iFlex™ Flexible Current Probe (included with the 376 FC, sold separately for the 375 FC and 374 FC), and provide increased measurement readings to 1000 A and 1000 V AC and DC. Three year warranty.
Recommended Accessories
TL224 SureGrip ™ Silicone Insulated Test Leads See page 141
TL223-1 SureGrip ™ Electrical
Test Lead Set See page 144
AC285 SureGrip ™
TL175 TwistGuard ™ Test Leads See page 140
Alligator Clips See page 141
C43 Small Soft Case See page 152
I2500-18 18 inch iFlex TM Flexible Current Probe See page 29
Included Accessories 18-inch iFlex™ Flexible Current Probe (Fluke 376FC only), Test Leads, Soft Carrying Case, Instruction Card, Safety Information Sheet, Two AA Alkaline Batteries. Ordering Information FLUKE 373 Fluke Connect ® Enabled The Fluke 376 FC, 375 FC, and 374 FC are a part of the Fluke Connect family of wireless test tools. • Trend measurements, pinpoint intermittent faults and transmit results wirelessly by connecting your meter to your phone via Fluke Connect Measurements app • Create and send reports right from the field • Stay safely away from the arc flash zone through Bluetooth connectivity
Fluke 376 FC with iFlex™
True RMS
Fluke 375 FC Fluke 374 FC Fluke 373
Functions
Range
373
374 FC 375 FC
376 FC
2% ± 5 counts
2% ± 5 counts
0 to 600.0 A 2% ± 5 counts
-
Current AC
0 to 999.9 A 0 to 600.0 A 0 to 999.9 A
- - -
-
-
2% ± 5 counts
2% ± 5 counts
2% ± 5 counts
-
Current DC
- -
- -
2% ± 5 counts
0 to 600.0 V 1% ± 5 counts
-
Voltage AC
1% ± 5 counts
1% ± 5 counts
0 to 1000 V
-
1% ± 5 counts
0 to 600.0 V 1% ± 5 counts
-
-
-
Voltage DC
1% ± 5 counts
1% ± 5 counts
0 to 1000 V
-
1% ± 5 counts
Resistance range Jaw opening Max. wire size
- - -
0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 60 kΩ
32 mm 34 mm 34 mm
34 mm
750 MCM 750 MCM 750 MCM 750 MCM
Frequency measurement range
-
-
-
500 Hz
500 Hz
True-RMS AC Clamp Meter
Fluke iFlex ™ Flexible Current Probe
FLUKE 374 FC
True-RMS AC/DC FC Clamp Meter True-RMS AC/DC FC Clamp Meter
Unprecedented measurement flexibility The iFlex Flexible Current Probe expands the measurement range of select Fluke Clamp Meters to 2500 A AC while providing increased display flexibility, improved wire access and the ability to measure awkward-sized conductors. Available in 18 inch and 10 inch coil sizes. • Compatible to Fluke 374 FC, 375 FC, 376 FC and 381 • CAT IV 600 V, CAT III 1000 V • 7.5 mm coil diameter allows measurement in tight spaces • 1.8 m cable • Three-year warranty Visit www.fluke.com/au/clamps for additional specifications.
FLUKE 375 FC
FLUKE 376 FC True-RMS AC/DC FC Clamp Meter with iFlex™ i2500-10 iFlex™ Flexible Current Probe 25 cm i2500-18 iFlex™ Flexible Current Probe 45 cm
C ontact your local distributor for price and availability. www.fluke.com/au/wtb
www.fluke.com/au/clamps
Clamp Meter
29
Made with FlippingBook Learn more on our blog