Fluke Australia 2020 Test Tools Catalogue

Fluke 902 FC True-RMS HVAC Clamp Meter

Recommended Accessories

Improve productivity in the field The Fluke 902 FC delivers the features necessary to diagnose and repair HVAC systems. Additionally, with Fluke Connect ® you can trend measurements, create and send reports right from the field, safely stay away from live equipment. Applications for HVAC • 200 µA DC current measurements to measure flame rod • Extended resistance range to measure thermistors up to 60kΩ • Capture flue gas temperature • Measure start and run motor capacitors

Fluke 902 FC

AC220

TL224 SureGrip™

SureGrip™ Alligator Clips

See page 141

Insulated Test Leads See page 141

• Measure performance of variable frequency drives • Temperature measurement from -10 °C to 400 °C • 1000 µF capacitance measurement • CAT III 600V, CAT IV 300V safety rating • Three year warranty

80PK 8 Pipe Clamp Temperature Probe See page 146

80AK-A Thermocouple Adapter See page 146

Functions

Range

Resolution Accuracy

A AC (via Jaw)

60/600 A

0.01/0.1 A 2.0 % ± 5 digit (45-65 Hz) 2.5 % ± 5 digit (65-400Hz)

V AC V DC

600 V 600 V

0.1 V 0.1 V

1.5 % ± 5 digit (45-400Hz)

Fluke 902 FC

1 % ± 5 digits

600/6,000 /60,000 Ω

Ohms

0.1/1/10 1 % ± 5 digits

C781 Meter Case See page 153

TPAK Magnetic Hanging Strap See page 154

True RMS

µA

200 µA

0.1 µA

1 % ± 4 digits

Contact Temperature 10 to 400

o C 0.1 C/F

1 % ± 8 digits

Capacitance 100.0/1000 µF 0.1/1 µF

1 % +/- 4 digits

Continuity Beeper Beep Volume 75 dBA nom. 15 cm from case front On Threshold <=30 Ω

Fluke 368 FC/369 FC AC True-RMS Leakage Current Clamp Meters

Measure leakage current to track small problems, avoid large problems The Fluke 360 Series of True-RMS Leakage Current Clamp Meters help users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, without taking equipment offline. • True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms • Jaw size: 40 mm (368 FC) and 61 mm (369 FC) • Current resolution 1 µA/0.01 mA and 0.01 A/0.1 A • Frequency range 40 Hz to 1 kHz • Selectable filter 40 Hz to 70 Hz or wideband 40 Hz to 1 kHz • Highest resolution of 1 μA, measure up to 60 A • Forward-facing LED worklight for use in dark wiring cabinets • Backlit display; auto backlight off and auto power off for extended battery life. • Wireless data connectivity via Fluke Connect • CAT III 600V safety rating • Three year warranty

Included Accessories

Ordering Information Fluke 368 FC/369 FC: Soft Case, Two AA Batteries, Safety Manual. Fluke 902 FC: TL75 Test leads, 80BK Integrated DMM Temperature Probe, Two AA Alkaline Batteries, Soft Carrying Case, Statement of Calibration Practices and User Manual. FLUKE 902 FC HVAC Clamp Meter FLUKE 368 FC AC Leakage Current Clamp Meter FLUKE 369 FC AC Leakage Current Clamp Meter

Fluke 369 FC

Fluke 368 FC

Specifications Measurement Function Alternating current AC Ampere Range

True RMS

3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A mA A: manual selection 3 mA, 30 mA, 300 mA: automatic selection 3 A, 30 A, 60 A: automatic selection

Range Selection

Frequency

40 Hz to 1 kHz

Crest Factor

Three

C ontact your local distributor for price and availability. www.fluke.com/au/wtb

32

Clamp Meters

Made with FlippingBook Learn more on our blog