Fluke Australia 2020 Test Tools Catalogue

Fluke 345 Power Quality Clamp Meter The ideal meter to troubleshoot modern electrical loads

Recommended Accessories

The Fluke 345 is more than just a power meter; it combines the functions of a clamp meter, oscilloscope, data logger and digital power meter into one handy device. The Fluke 345 is ideal for working with variable frequency motor drives, high efficiency lighting and other loads using switching electronics. • AC/DC current: Clamp-on measurement of AC current up to 1400 A RMS and DC current up to 2000 A without breaking the circuit • Highest safety rating: CAT IV 600 V power analyser is rated for use at the service entrance • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics • Troubleshoot harmonics: Analyse and log harmonics digitally or graphically • Inrush current: Capture and analyse nuisance tripping from 3 seconds to 300 seconds • View graphs and generate reports: Use power analyser with included Power Log software • Three phase power: Built-in capability for balanced loads • Verify batteries: Direct measurement of DC ripple (%) for battery and DC systems • One year warranty

TP1 Slim Reach Test Probes See page 141

TP220 Industrial Test Probes See page 141

TLK291 Fused Test Probe Set See page 142

AC220 Alligator Clips See page 141

L200 Probe Light See page 154

C550 Tool Bag See page 153

Fluke 345

Current measurement

All measurements DC and 15 Hz to 1 kHz. Maximum overload 10,000 A or RMS x frequency < 400,000. Amps RMS is a true RMS measurement (AC + DC)

DC, DC RMS, AC RMS

Measuring range

0 – 2000 A DC or 1400 AC RMS

View waveforms for equipment checking and setup

All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Harmonics

Voltage measurement DC, DC RMS, AC RMS

All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000 V RMS. Volts RMS is a true-RMS measurement (AC + DC)

Measuring range

0 – 825 V DC or AC RMS

All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Vacrms > 1V

Harmonics

Watts measurement (single-and three-phase)) DC, DC RMS, AC RMS Measuring range 0 – 1650 kW DC or 1200 kWAC VA measurement (single-and three-phase) DC, DC RMS, AC RMS Measuring range 0 -1650 kVA DC or 1200 kVA AC VAR measurement (single-and three-phase) Measuring range 0 – 1250 kVAR Power factor (single-and three-phase) Measuring range

Log parameters over time to track down intermittent faults

0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)

Displacement power factor Measuring range

0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)

Kilowatt hour (kWHr) Measuring range

40,000 kWHr

Scope function Time base

Included Accessories Soft Carrying Case, PowerLog Software, Test Probes, Test Leads, Alligator Clips, AC Adapter/Battery Eliminator, User Manual.

2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div Inrush current function All measurements DC and 15 Hz to 1 kHz Ranges 40, 400 and 2000 A Memory Up to 50 screen shots and over 150,000 individual measurement values

Ordering Information

FLUKE-345

Power Quality Clamp Meter

C ontact your local distributor for price and availability. www.fluke.com/au/wtb

www.fluke.com/au/PQ

Power Quality Analysers

85

Made with FlippingBook Learn more on our blog