Fluke 1750/ET Three-Phase Power Quality Recorder
Record every power quality parameter, every cycle, all the time Setting up a Power Quality Analyser to capture detailed power quality data has never been easier than it is with the Fluke 1750ET. This Fluke Three-Phase Power Recorder captures the most important data for up to 30 days. It automatically records every power quality parameter and event, on every cycle – all the time. Once the data is captured; download via Ethernet or directly to the 2GB SD card (without the need of any other device). The Fluke 1750/ET features a wireless front panel for viewing measurements, data and setting up, implemented via a tablet computer using Bluetooth communication. • Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc
Recommended Accessories
3210-PR-TF-II 1000A Thin flexible current transformer 61cm (24”) (20A – 1000A) See page 160
3140R 400A, Clamp-on Current Transformer See page 160
3310-PR-TF-II 5000A Thin flexible current transformer 61cm (24”) (100A – 5000A) See page 160
I40S-PR 40A Current Clamp See page 160
Fluke 1750/ET
• Quick and reliable configuration: PDA wireless “front panel interface” provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations • Threshold-free set up: Apply thresholds after data is collected with Fluke Power Analyse Software—no need to worry about missed information due to incorrect setups • Windows 10 tablet for control, setup, data download and analysis • Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time • Measure every parameter: Voltage and current on three phases, neutral and ground • 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events • Plug and play: Set up in minutes with self-identifying current probes and single-lead voltage connections • No need to reconnect wires: Swap channels internally with the wireless front panel or PC when connections are not correct • One year warranty
3312-PR-TF-II 5000A Thin flexible current transformer 122cm (48”) (100A – 5000A) See page 160
I5S-PR 5A Current Clamp See page 160
CS1750/1760 Soft Case for 1750 & 1760 See page 160
1750/CASE Transit Case See page 160
Power Quality Measurement Standards Conformance
IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160
Clock/calendar
Leap years, 24-hour clock Not more than ± 1 s/day
Real-time clock accuracy
Internal memory capacity for data At least 2 GB Maximum recording period At least 31 days Measurement time control Automatic Maximum number of events
Limited only by the size of the internal memory 100 to 240 V RMS ± 10 %, 47-63 Hz, 40 W
Power requirements
Operating time during interruptions (internal UPS operation)
5 mins per interruption, 60 mins total operating time without recharging
Size
215 mm x 310 mm x 35 mm
Weight
6.3 kg
Included Accessories
Lenovo Miix 310 Windows 10 PC Tablet, 4 x 400A Amperage Clamps (3140R), 5 x Test Leads and Clips, SD Memory Card, Fluke Power View and Fluke Power Analyse Software, Power Cord, Ethernet Cable, Colour Localisation Set, Getting Started Manual, Product CD with Software, User Manual (PDF), CS1750/1760 Rugged Transit Carrying Case.
Apply thresholds to data after collection using a variety of standard or customised templates.
Simplified report writer feature included in Fluke Power Analyse Software.
Ordering Information
Three-Phase Power Quality Recorder
FLUKE-1750/ET