Webasto Marine Catalog 2024 EN

BlueCool S-Series Self contained units

BlueCool S-Series

Technical data

Technical data

BlueCool S-Series 230 V

BlueCool S-Series 115 V

Type

S6

S8

S10

S13

S16

S20

S27

Type

S6

S8

S10

S13

S16

Order numbers

WBCL120000C WBCL120001F WBCL120002F WBCL120003F WBCL120004G WBCL120005F WBCL120006G

Order No.

2510139C

2510140C

2510141C

2510142C

2510142C

Cooling capacity* (BTU / h)

6,000

8,000

10,000

13,000

16,000

20,000

27,000

Cooling capacity* (BTU / h)

6,000

8,000

10,000

13,000

16,000

Cooling capacity* (kW)

1.8

2.4

2.9

3.8

4.7

5.9

7.9

Cooling capacity* (kW)

1.8

2.4

2.9

3.8

4.7

Heating via reverse cycle integrated

yes

yes

yes

yes

yes

yes

yes

Heating via reverse cycle integrated

Yes

Yes

Yes

Yes

Yes

Voltage (V)

230 (-15% / +10%) 50 / 60 (+-5%)

230 (-15% / +10%) 50 / 60 (+-5%)

230 (-15% / +10%) 50 / 60 (+-5%)

230 (-15% / +10%) 50 / 60 (+-5%)

230 (-15% / +10%) 50 / 60 (+-5%)

230 (-15% / +10%) 50 / 60 (+-5%)

230 (-15% / +10%) 50 / 60 (+-5%)

Voltage (V)

115 (-15% / +10%)

115 (-15% / +10%)

115 (-15% / +10%)

115 (-15% / +10%)

115 (-15% / +10%)

Frequency (Hz)

60 (+-5%)

60 (+-5%)

60 (+-5%)

60 (+-5%)

60 (+-5%)

Frequency (Hz)

Current draw running** (A) 60 Hz

3.6 – 5.5

4.5 – 6.1

5.6 – 7.9

7.6 – 11

8.0 – 15.7

Current draw running** (A) 50 Hz

2 – 2,4

2.4 – 3.5

2.6 – 4.0

3.6 – 6.3

4.9 – 7.1

5.9 – 8.9

7.0 – 10.5

Current draw max. peak (A) 60 Hz

39

54

55

70

89

Current draw max. peak (A) 50 Hz

14

28

27

37

54

60

77

Current draw RMS40**** (A) 60 Hz

25

35

36

47

59

Current draw RMS40**** (A) 50 Hz

5

17

17

22

35

39

49

Current draw RMS300*** (A) 60 Hz

19

20

21

30

35

Current draw RMS300*** (A) 50 Hz

3

9

9

11

19

20

32

Locked Rotor Amperage LRA (A)

27

34

37

57

70

Current draw max. peak with Soft Start (A) 50 Hz Current draw RMS40**** with Soft Start (A) 50 Hz Current draw RMS300*** with Soft Start (A) 50 Hz Locked rotor amperage LRA (A)

11

12

11

13

22

23

34

Max. circuit breaker (A)

16

16

16

16

25 (compressor only)

4

7

7

7

12

14

19

Air flow (free blowing) (m³ / h) Air flow (free blowing) (cfm / h) Seawater connection (mm) Seawater connection (inch)

275 162 19 3 / 4

275 162 19 3 / 4

350 206 19 3 / 4

430 253 19 3 / 4

650 382 19 3 / 4

3

5

5

5

9

10

17

12

19

19

24

37

43

62

Minimal Seawater flow (l/min) 60 Hz

6

8

10

12

14

Max. circuit breaker (A)

16

16

16

16

16

16 20 (comp. only)

Recommended seawater pump 60 Hz + Dimensions L x W x H (mm) Dimensions L x W x H (inch)

WB250

WB350

WB350

WB350 WB500G

WB500 WB500G

Air flow (free blowing) (m³/ h) Air flow (free blowing) (cfm) Seawater connection (mm) Seawater connection (inch) Min. seawater flow at 50 Hz (l/min)

275 162 19 3 / 4

275 162 19 3 / 4

400 235 19 3 / 4

500 294 19 3 / 4

625 368 19 3 / 4

625 368 19 3 / 4

2 x 550 2 x 324

405 x 320 x 300 15.9 x 12.6 x 11.8

405 x 320 x 305 15.9 x 12.6 x 12.0

480 x 335 x 315 18.9 x 13.2 x 12.4

510 x 345 x 325 20.1 x 13.6 x 12.8

550 x 340 x 370 21.7 x 13.4x 14.6

19 3 / 4

Blower connection (mm) Blower connection (inch)

100 4

100 4

100 4

125 5

125 5

6

8

10

12

14

17

21

Min. seawater flow at 60 Hz (l/min)

7,5

10

12

14

17

20

25

Weight (kg)

18

18

20

25

29

Recommended seawater pump +

WB250

WB350

WB350

WB350 / WB500G

WB500 / WB500G

WB500 / WB500G

WB1000 / WB1000G

* BTU / h are based on 7 °C evaporating temperature and 38 °C condensing temperature ** values for core unit depend on compressor load. Max values at tropical conditions at 115 V / 60 Hz

Dimensions L x W x H (mm) Dimensions L x W x H (inch) Blower connection (mm) Blower connection (inch)

510 x 350 x 325 20.1 x 13.8 x 12.8

4 05 x 320 x 305 15.9 x 12.6 x 12.0

550 x 350 x 370 21.7 x 13.8 x 14.6

595 x 340 x 370 23.4 x 13.4 x 14.6

575 x 515 x 410 22.6 x 20.3 x 16.1

405 x 320 x 305 15.9 x 12.6 x 12.0

480 x 335 x 315 18.9 x 13.2 x 12.4

*** Starting amperage RMS (Root Mean Square) for core unit for first 300 ms **** Starting amperage RMS (Root Mean Square) for core unit for first 40 ms + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow.

100 4

100 4

100 4

125 5

125 5

125 5

2 x 125 2 x 5

Weight (kg)

20

20

22

27

31

34

46

Schematics S27-Series

General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU / h are based on 7 °C evaporating temperature and 38 °C condensing temperature ** Amperage values for core unit depend on compressor load. Max values at tropical conditions at 230 V / 50 Hz *** Starting amperage RMS (Root Mean Square) for core unit for first 300 ms **** Starting amperage RMS (Root Mean Square) for core unit for first 40 ms + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow.

Schematics S-Series

H

H

D W

D W

L

L

S6 – S20

S27

Soft start device available as an option

BlueCool Expert, Display and Temperature Sensor access from outside

24.10.2012

Schematics S- und C-Series

94

95

23.10.2012

Schematics S- und C-Series

2

Made with FlippingBook Digital Proposal Creator