Trex RainEscape® Installation Guide

8. INSTALLING A GUTTER SYSTEM (not included)

7. INSTALLATION OF FASCIA » Deck board go over fascia. (7)

» Before installing a gutter system perform a water test to clean out the system and check for any leaks. » Attach a standard gutter system to collect the water from the Trex RainEscape downspouts.

7

SIDE VIEW

TROUGH

TAPE

BUTYL CAULK

8A

FRONT VIEW

BUTYL CAULK

SOFFIT

SOFFIT

2 x 4 ACCESS PANEL

ATTACH A STANDARD GUTTER SYSTEM (NOT INCLUDED) TO COLLECT THE WATER FROM THE TREX RAINESCAPE DOWNSPOUTS

TROUGH

TAPE

NOTE: Installing a clean-out trim piece will allow access to gutter line after installation.

DECKING

FASCIA

8B

SIDE VIEW

BUTYL CAULK

DOWNSPOUT SHOULD EXTEND ABOUT 1" INTO THE GUTTER

BUTYL CAULK

SOFFIT

SOFFIT

2 x 4 ACCESS PANEL

WE SUGGEST INSTALLING A 2x4 or 2x6 ACCESS PANEL TO CHECK GUTTER WITHOUT REMOVING SOFFIT

8C

FOR 2 x 12 JOIST EXTEND THE DOWNSPOUT USING A STANDARD GUTTER DOWNSPOUT AND TRIMMED TO LENGTH

SCREW GUTTER TO DOWNSPOUT

FOR 2 x 6 OR 2 x 8 JOIST, DOWNSPOUT NOZZLE CAN BE CUT TO LENGTH

8D

ATTACHING THE GUTTERS

ATTACH A PIECE OF L-METAL TO THE GUTTER, THEN TO THE BOTTOM OF THE JOIST

CUT A TAB ON THE TOP OF THE GUTTER AND FOLD OVER ATTACH TO THE BOTTOM OF THE JOIST

10

Made with FlippingBook - professional solution for displaying marketing and sales documents online