ENGINEERING DATA HEATER GAS SUPPLY AND PIPE SIZING INFORMATION
When installing any Pentair or Sta-Rite pool or spa heater, it is very important to have the proper amount of gas supplied to all Pentair or Sta-Rite Heaters for pools. Below, for your information, is a table which will assist you in selecting the correct size of piping for the installation. When installing any gas appliance, it is very important to have the proper size gas meter and home pressure regulator installed. Once you have selected the correct size heater for the pool or spa, contact the local utility which supplies the gas and request a field review of the installation and have them install the proper size meter and proper size pressure regulator.
LOW PRESSURE, SINGLE STAGE PIPE SIZING FOR GAS LINE CONNECTIONS
4 Natural gas at 1000 BTU per Cubic Foot Propane Gas at 2500 BTU per Cubic Foot
1/2 in. 2-1/2 in. NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO 3/4 in. 1 in. 1-1/4 in. 1-1/2 in. 2 in.
MODEL
600 ft. 600 ft.
100 & 75 20 ft.
50 ft.
50 ft.
150 ft. 150 ft.
-
-
-
-
-
-
-
-
150
10 ft.
40 ft.
50 ft.
150 ft. 150 ft.
-
-
-
-
-
-
-
-
200 250 300 350 400 525 750 900
- - - - - - - -
20 ft. 10 ft.
30 ft. 20 ft. 10 ft. 10 ft.
80 ft. 50 ft. 30 ft. 20 ft. 10 ft.
125 ft. 250 ft. 450 ft. 600 ft.
-
- -
- - -
- - - - -
- - - - - - -
- - - - - - - -
70 ft.
150 ft. 250 ft. 500 ft. 600 ft.
- - - - - -
50 ft. 100 ft. 200 ft. 350 ft. 400 ft. 600 ft.
30 ft. 20 ft. 15 ft.
70 ft.
125 ft. 250 ft. 250 ft. 500 ft. 500 ft.
- - - -
60 ft. 100 ft. 150 ft. 200 ft. 450 ft. 400 ft.
5 ft.
35 ft. 20 ft. 15 ft.
65 ft. 35 ft. 20 ft.
150 ft. 130 ft. 360 ft. 390 ft. 700 ft.
- -
- -
80 ft. 45 ft.
75 ft. 45 ft.
180 ft. 260 ft. 600 ft.
100 ft. 150 ft. 360 ft. 400 ft.
Natural
Propane
Natural
Propane
Gas Pressure Model
Gas Pressure
Inches W. C. Gas Pressure Requirements Pentair Water Heaters
Inches W. C. Gas Pressure Requirements for MiniMax 75 & 100 Pentair Water Heaters Normal Altitudes (0–2500 ft. above Sea Level) Maximum Inlet 10 14 Minimum Inlet 5 12 Normal Manifold 4 11 High Altitudes (2500–7000 ft. above Sea Level) Maximum Inlet 10 14 Minimum Inlet 5 12 Normal Manifold 3 7 Note: All readings must be taken while heater is operating. Any adjustments or readings made while heater is off will give incorrect readings and should not be used for evaluation of heater operation. All Values are +/- 0.2 inch W. C.
CH
10 10 10 10
14 14
STD
Maximum Inlet
TSI LN CH
N/A N/A
6 6 4 6 4 4 2 4
12 12
STD
Minimum Inlet
TSI LN CH
N/A N/A
11 11
STD
Manifold
TSI
N/A N/A
LN
Natural
Propane
Gas Pressure Model
Inches W. C. Gas Pressure Requirements for MasterTemp, Max-E-Therm and ETi 400 Pentair Water Heaters Maximum Inlet MT 14 14 Minimum Inlet MT 4 4 Manifold MT -0.2 ± 0.1 -0.2 ± 0.1
536