Screws: Only use screw that are compatible with the individual screw presenter model. Do not use oily screws, dirty screws, or any screw other than those prescribed. Avoid overloading the screw presenter with too many screws. The level of the screws should be below the internal rail system. If too many screws are thrown in, orientation and transfer of the screw will be seriously affected.
The screw output is from 60 ~ 90pcs/min
MSP screw presenter container volume of 200ml. (to calculate screw capacity)
Functionality Adjustments
Feeding Speed Regulation – Menu A
Press down arrow for 3 seconds to select the first menu option
Feeding Speed Regulation – Menu A
Press the down arrow or up arrow to adjust the value
Range is A -1 to A-30
Press SET to save and navigate to the next menu selection
Vibration Motor Delay Stop Time – Menu B
If not already in the menu selection mode, Press Down Arrow for 3 seconds Press SET button one time to select the Vibration motor delay stop time – Menu B
Press the down arrow or up arrow to adjust the value
The range is 0.0 to 6.0 Sec (B – 00 – B – 60)
Increments are 0.5 sec
Press SET to save and navigate to the next menu selection
Made with FlippingBook Annual report maker