3.3.2 Point 2 At the south curb of Satinloaf Drive 59 feet from the pickleball courts fence. Center of east side of courts on axis of play. Ground was asphalt.
Figure 3.6. Sound Level Meter at Point 2
Table 3.5 shows a summary of the entire measurement for each ball at Point 2. This data contains frequent events not related to pickleball and is similar to the background noise measurement.
Ball
Start Time End Time LAeq C.I. 95% LAmax LA10 LA50 LA90
Foam Quiet Monarch
09:30:25 09:35:29 52.2 1.0 10:14:03 10:21:24 54.7 0.7 10:53:39 11:01:21 56.4 1.4 11:36:35 11:43:30 56.9 0.7
67.4 55.0 50.2 46.6 67.8 58.1 52.2 47.8 71.2 59.8 52.3 47.0 73.3 60.5 53.4 47.8
Onix
Dura 40
Table 3.5. Sound Pressure Level Data Summary at Point 2
Table 3.6 shows the A-weighted equivalent-continuous sound pressure level for only pickleball. These levels do not include any adjustment for the impulsive nature of the paddle and ball
19 of 58 Spendiarian & Willis Acoustics & Noise Control LLC
12/15/2019
Made with FlippingBook - professional solution for displaying marketing and sales documents online