Directors Report

Figure 6.1. Pickleball Court Noise Abatement Plan for Dura 40 Ball

Drawing Notes 1. Dimensions are approximate and may not reflect the exact measurements of the existing pad. Wall positions may be adjusted up to 5 feet' to accommodate existing masonry, landscaping, etc. 2. Height of wall to be 10.0 feet minimum above court surface. Court facing surface of wall to be acoustically absorptive. Minimum absorption coefficient to be 0.9 at 1,000, 2,000, and 4,000 Hz. 3. Height of wall to be 8.0 feet minimum above court surface. Length of wall to be 40 feet minimum centered on gap between perimeter walls. Court facing surface of wall to be acoustically absorptive. Minimum absorption coefficient to be 0.9 at 1,000, 2,000, and 4,000 Hz. 4. Passage width and gap between perimeter walls may not exceed 6.5 feet.

A recommended wall system is SonaGuard made by Sound Fighter Systems (see soundfighter.com). Absorption for this wall system is rated at NRC 1.05 with a sound transmission class of STC 35 and five pound per square foot surface weight. Similar products are

36 of 58 Spendiarian & Willis Acoustics & Noise Control LLC

12/15/2019

Made with FlippingBook - professional solution for displaying marketing and sales documents online