PAAS SB V5.1

Industrial Grey PVC-U Pipe And Fittings Level

Echo Pulse

EchoPulse ® General Purpose Pulse Radar Liquid Level Transmitters ` Best for Difficult Bulk Tank, Process or Sump Applications

These non-contact sensors are the reliable level measurement solution for your most demanding storage, process and lift station applications.

Why Pulse

Technology

Pulse radar is unaffected by process conditions that cause other sensing technologies to fail or require ongoing maintenance. These include foam, vapor, condensation, corrosion, temperature, pressure, vacuum, and coating or scaling liquids

The radar sensor emits a 26 GHz or 6.3 GHz RF pulse from the base of the an- tenna. The pulse travels through the free space, reflects against the liquid dielectric material and returns to the antenna. The sensor measures the pulse time of flight and translates it into liquid level distance.

The LR30 pulse radar sensor is the reliable level measurement solution for municipal and industrial pump lift stations.

LR10

LR15

LR20

LR30

Classification

General purpose

Application

Storage

Storage

Storage

Lift station

Proc. condition

Easy

Difficult

Difficult

Difficult

Tank location and material

Above grade metal or below grade in any tank material

Above or below grade in any tank material

Above or below grade in any tank material

Below grade in any tank material

Corrosive

Yes

Diluted

Yes

Diluted

Range

10m

30m

20m

30m

Output

4-20 mA

4-20 mA

4-20 mA

4-20 mA

Configuration

Push button

Push button

Push button

Push button

Installation

Tank adapter or flange

Flange

Bracket

Mount

1 1/2’’ NPT

1 1/2’’ NPT

3’’, 4’’ ANSI

Bolt

Max. temp

130 °C

150 °C

150 °C

100 °C

Max. Pressure

3 bar

10 bar

5 bar

Atmospheric

Ant. material

PFA

316L

316L & PTFE

Nylon

Level Controllers and Indicators ` Best for Tank, Sump or Silo Automation

Complete your level measurement solution with a panel or field mount relay controller or indicator

LI55

LC52

LI25-1

LI25-2

Classification

General purpose

General purpose

General purpose

Intrinsically safe

Type

Controller

Controller

Indicator

Indicator

Application

Display + control

Display + control

Display only

Display only

Mount

Panel mount

Rail Mount

Panel mount

Panel mount

Display

6-digit LED

3.5-digit LED

5- digit LED

5-digit LED

Supply

85-265 VAC, 12-24 VDC (0,2,4) SPDT relay

120 /240 VAC

12-30 VDC loop

12-30 VDC loop

Contact

2 SPDT relays

---

---

Enclosure

NEMA 4X faceplate

NEMA 1

NEMA 4X faceplate NEMA 4X faceplate

1300 PIPING (1300 747 464) PAAS Source Book 217

V 5.1