Solenoid Operated Directional Valve DG4V-3-60 Design

DG4V-3 High Performance Valves • Available with manual overrides for industrial or water-resistant overrides for mobile applications. • Minimum pressure drop 2.5 Bar at 30 lpm.

General Description Solenoid operated directional control valves are for directing and stopping n ow at any point in a hydraulic system. • Efm cient control of greater hydraulic powers without increasing solenoid power consumption. • Installed cost and space savings from higher power/weight-and-size ratios. • Installation n exibility resulting from choice of numerous combinations of solenoid connectors and locations. • Viton seals as standard for multi- n uid capability. Nitrile seals available as a model code option.

• Higher sustained machine productivity and higher uptime because of proven fatigue life and endurance, tested over 20 million cycles. • Solenoid coils can be changed quickly and easily without leakage from hydraulic system. • Compact, cost effective system design when used with Vickers SystemStak™ valves and subplates.

• Range of coil voltages. • Up to 80 lpm at 350 Bar.

• Offers designers the opportunity to select the optimum value package for each application. • International standard interface. The valve mounting face conforms to ISO 4401, size 03 and is compatible with related international standards. • Alternative coil voltages and connectors such as Deutsch, Amp and terminal box are available, contact sales ofm ce for a quotation.