Flowtech Catalogue

1

HYDRAULIC FLOW METERING

Easiflow Meter

Fluid Level & Temperature Gauges

Dataflow In-line Flow Indicatio

Maximum Working Pressure: 10 bar Oil/water Working Temperature: +5ºC to +80ºC Oil +5ºC to +60ºC Water

Maximum Working Pressure: 10 bar Working Temperature: +5ºC to +80ºC +60ºC with water

Maximum Working Pressure: 1 bar Working Temperature: -30ºC to +90ºC

• Indicator gives flow visibilit • Works in any plane • Accepts reverse flo • Indicates flow from 2-150 L/mi

• Oil and water calibrated • Works in any plane • Pressures up to 10 bar • Switches – Fully adjustable flow rate signalling • Plant and equipment protection • Switches – Colour coded by application and AC/DC options Construction: Cone: Acetal Viewing Glass: Borosilicate glass Calibrated Spring: Stainless steel Seal: Nitrile Body: Glass filled nylo Flow Range: 1-150 L/min Viscosity Range: 10-200 centistrokes Accuracy: œ5% FSD Repeatability: œ1% FSD Connections: 1” BSPP Weight: 0.4kg

Construction: • Lens transparent polyamide • Lens base nylon 66 • No aluminium content • Shroud high impact polystyrene Seals: Nitrile. Fluid Compatibility: Mineral and petroleum based fluids

Indicator 0045

Description

DFI900

Dataflow Indicator

Tech Sheet 1341

Hydraulic Test Unit

Fluid Level

Fluid Level Temperature

Hydraulic test units are designed specifically for the speedy diagnosis of hydraulic circuit faults in mobile, marine and industrial systems using normal range of mineral oils, their rugged construction based mainly on mild steel, manganese bronze and acrylic materials

makes them ideally suited for arduous use in the field Each unit is supplied in a convenient carrying case providing full protection and additional storage space for fittings. Because they need no power source such as batteries etc, they are always ready for instant use. The scale on the flow meter can be rotated to ensure visibility in any situation and the installed attitude is not critical, though whenever possible the unit should be monitored with pressure gauge vertical and gauge case relief valve uppermost. The unit is designed for flow to be in the direction of the arrow on the flow meter scale and must not be installed with the flow reversed Safety An axial flow restrictor valve is fitted which can b adjusted under full load from open to fully closed, and to complete the specification, a safety blow out disc, set to operate at 455 bar is fitted to the manifold in a position facing away from the operator when reading the gauges normally. Two spare blow out discs are supplied which are easily replaced by removing the hexagonal plug on the gauge manifold. • Speedy diagnosis of hydraulic circuit faults • Flows ranging from 2-360 L/min • Measuring flo , pressure and temperature • Portable. No power source required • Hydrotrac unit for flows from 2-110 L/min availabl

Oil

Fluid Level 0045

0045

LPM 2-30 4-50 5-100

Centres mm

Thread

EFL0301 EFL0501 EFL1001 EFL1501

FL111 FL211 FL311 FL112 FL212 FL312

76

M10 M10 M10 M12 M12 M12

127 254

10-150

76

127 254

Tech Sheet 10301

Fluid Level Temperature 0045 Centres mm

Thread

FLT121 FLT221 FLT321 FLT112 FLT212 FLT312

76

M10 M10 M10 M12 M12 M12

127 254

76

127 254

Water 0045 EFW0152 EFW0302 EFW0502 EFW1002 EFW1502

Tech Sheet 10301

LPM 1-15 2-30 4-50 5-100

Maximum Working Pressure: 350 bar

Working Temperature: 0ºC to +100ºC Flow Range: 10-110 L/min

BSPP 0045

10-150

Thread

4121

3/4”

252

Made with FlippingBook - professional solution for displaying marketing and sales documents online