Flowtech Catalogue

1

HYDRAULIC FILTRATION

The UFI Hydraulic Division return filters are named ‘ ANK CARE’ because they take care of the oil returning into the tank, ensuring the fluid cleanliness level to be within the required values. Nominal flow rates up to 2.400 L/mi (635 GPM). Degree of filtration is from 5˜m(c) to 90˜m. Filter elements are glass fibre, cellulose and metal wire mesh media. Materials: • Aluminium alloy head and cover • Polyamide bowl for FRA21-31-32-33-41 • Zinc-plated steel bowl for FRA41-42-51-52-53-5D • Polyamide bypass valve • NBR nitrile seals (FKM fluoroelastomer on request • Brass indicator housing Compatibility: (ISO 2943:1999) • Full with fluids: HH-HL-HM-H -HTG (according to ISO 6743/4)

Pressures: (ISO 10771-1:2002) • Maximum working: 1,2 MPa (12 bar) • Test: 1,5 MPa (15 bar) • Bursting: 2,5 MPa (25 bar) • Collapse differential for the filter element (ISO 2941): 400 kPa (4 bar)

Compatibility: (ISO 2943:1999) • Full with fluids: HH-HL-HM-HR-HV-HG (according to ISO 6743/4)

Materials: • Aluminium alloy head • Steel spin-on cartridge • Polyamide bypass valve • NBR nitrile seals (FKM fluoroelastomer on request • Brass indicator housing

PE Series Filters, Spin-on

Maximum Working Pressure: 12 bar

Working Temperature: -25°C to +110°C

RA Series Filters, Tank Return

Single, BSPP Ported, Visual Indicator, Bypass 1.7 bar, 12 Micron

Replacement Fibre Elements 0526 Filter Element Size

Working Temperature: -25°C to +110°C Maximum Working Pressure: 3 bar

Micron

Filter Element Size

ESE11NFA ESE11NFB ESE11NFC ESE11NFD ESE12NFA ESE12NFB ESE12NFC ESE12NFD ESE21NFA ESE21NFB ESE21NFC ESE21NFD ESE22NFA ESE22NFB ESE22NFC ESE22NFD

11 11 11 11 12 12 12 12 21 21 21 21 22 22 22 22

5 7

0526

Thread

FPE11B06BNFC31XX FPE12B06BNFC31XX FPE21B10BNFC31XX FPE22B10BNFC31XX

3/4” 3/4”

11 12 21 22

12 21

BSPP Ported, Visual Indicator, Bypass 1.7 bar, 12 Micron

1.1/4” 1.1/4”

5 7

12 21

Filter Element Size

0526

Thread

FRA21B04BNFC32WX FRA31B06BNFC32WX FRA32B08BNFC32WX FRA41B10BNFC32WX FRA51B12BNFC32WX FRA53B16BNFC32WX

1/2” 3/4”

21 31 32 41 51 53

5 7

1”

12 21

1.1/4” 1.1/2”

5 7

2”

Tech Sheet 68077

12 21

BSPP Ported, Visual Indicator, Bypass 1.7 bar, 21 Micron

Tech Sheet 68078

Filter Element Size

The UFI Hydraulic Division clogging indicator gives an exact indication of the proper time to replace the filter element

0526

Thread

Twin, BSPP Ported, Visual Indicator, Bypass 1.7 bar, 12 Micron

FRA21B04BNFD32WX FRA31B06BNFD32WX FRA32B08BNFD32WX FRA41B10BNFD32WX FRA51B12BNFD32WX FRA53B16BNFD32WX

1/2” 3/4”

21 31 32 41 51 53

1”

1.1/4” 1.1/2”

Filter Element Size

0526

Thread

2”

FPE31B12BNFC31XX FPE32B12BNFC31XX

1.1/2” 1.1/2”

31 32

Replacement Fibre Elements 0526

Clogging Indicators, Visual 0526

Filter Element Size

Micron

Thread

ERA21NFC ERA31NFC ERA32NFC ERA41NFC ERA51NFC ERA53NFC ERA21NFD ERA31NFD ERA32NFD ERA41NFD ERA51NFD ERA53NFD

21 31 32 41 51 53 21 31 32 41 51 53

12 12 12 12 12 12 21 21 21 21 21 21

31-PEIND

1/8”

Dual, BSPP Ported, Visual Indicator, Bypass 1.7 bar, 12 Micron

Filter Element Size

0526

Thread

FPE41B12BNFC31XX FPE42B12BNFC31XX

1.1/2” 1.1/2”

41 42

259

Made with FlippingBook - professional solution for displaying marketing and sales documents online