Flowtech Catalogue

PRESSURE BOOSTERS

Air Pressure Booster

The air-to-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally used to locally intensify the input pressure of one or more actuators. As it is entirely pneumatic it can be used when electric devices are not recommended. The booster can be supplied with or without a pressure regulator.

It is mtted with check valves that maintain the outlet pressur e even when the supply of compressed air is switched off. This means it is necessary to interrupt the supply and relieve the circuit before intervening on the device in any way. It is advisable to install a tank after the booster to prevent nuctuations in outlet pressur e.

Technical Data

Booster Ø40

Booster Ø40 with regulator

Booster Ø63

Booster Ø63 with regulator

Bore Fluid

 40

 63

Filtered unlubricated compressed air. Lubrication, if used, must be continuous.

Threaded port

G1/8

G3/8

5

MPa

0.2-1 2-10

Inlet pressure

bar psi

29-145

MPa

Maximum 2 Maximum 20 Maximum 290 -10 to +60 +14 to +140

Maximum 1.6 (regulated) Maximum 16 (regulated) Maximum 232 (regulated)

Maximum 2 Maximum 20 Maximum 290

Maximum 1.6 (regulated) Maximum 16 (regulated) Maximum 232 (regulated)

Outlet pressure

bar psi

ºC ºF gr

-10 to +50 +14 to +122

-10 to +60 +14 to +140

Operating temperature

Weight

1.380

1.600

4.240

5.350

Mounting Installation

Wall or panel In any position

 63

 40

Without Regulator 9146

Description

9002100 9002300

40mm Diameter Booster , 12 Ratio 63mm Diameter Booster , 12 Ratio

Air Regulators

To suit Air Pressure Multiplier (Booster) 9193 Description 9002180 40mm Regulator Unit 9002380 63mm Regulator Unit