AIRWAY ACCESSORIES
74
N E W ★
Double Swivel Endotracheal Tube Connector with Capped Port Multi-axial rotation allows for patient adjustment and manipulation with reduced risk of ET tube movement while maintaining ventilation. • Integrated access port for bronchoscopy, BAL, and suction without circuit disconnection • M aintains seal around scope during bronchoscopy procedure; seal accepts bronchoscope diameters from 3.4 to 5.9mm • 3 60° Double Swivel Feature - both the male and female 15mm connectors allow greater patient maneuverability between endotracheal tube and anesthesia circuit ITEM # SC15MM
360º • 1 5mm connector with luer lock sampling side port to replace standard 15mm adapter on endotracheal tubes • L ow dead space design decreases the mechanical dead space and subsequent CO 2 rebreathing • A llows for administration of medications and surfactants as well as monitoring of pressure and gas DESCRIPTION ITEM # 2.5mm ID ETA25 3.0mm ID ETA30 3.5mm ID ETA35 4.0mm ID ETA40 5.0mm ID ETA50 8.0mm ID ETA80 Low Dead Space Endotracheal Tube Adapter with Luer Sampling Port
Port for Bronchoscope
Connect to Anesthesia Circuit
Airway/ET Tube Exchange Catheter
Great addition to your ventilator patient supplies
Connect to Endotracheal Tube
• Intended for easier, atraumatic endotracheal tube exchange; NOT FOR VENTILATING THE PATIENT • U seful for oxygenating during fluoroscopy • 1 5mm adapter allows oxygen to be delivered temporarily - the adapter is removed in order to slide out the existing endotracheal tube and slide in the replacement tube • C entimeter markings for alignment with endotracheal tube markings • P olished, atraumatic, open-ended catheter with side-holes
Atomizer/Throat Sprayer
Use to deliver atomized topical anesthetic into the upper airway to reduce sensation and reflexes that can be triggered by intubation, endoscopy, etc. • 1 5Fr (4.7mm) tip x 15cm (6.5in) malleable, wire-reinforced tube for targeted deposition of medication
• P riming volume is 0.2mL • U se a 3mL syringe for a minimum forecast distance of 10cm upon exiting the sprayer tip under 25Kpa pressure to form an area of diameter of no less than 7cm
Atomize medication into a fine mist of 50-80 micron particles
DESCRIPTION
FITS TUBE SIZES (ID) larger than 3.0mm larger than 4.0mm larger than 4.0mm larger than 6.0mm
ITEM #
8Fr x 80cm (32in) 10Fr x 80cm (32in) 10Fr x 150cm (60in) 15Fr x 80cm (32in)
ETE0880 ETE1080 ETE10150 ETE1580
ITEM #
5380
Made with FlippingBook Learn more on our blog