2025 MILA Product Catalog - International

Tracheal Wash & Bronchoalveolar Lavage (BAL) – Small Animal

Blind Method (Tube through Sterile Endotracheal Tube)

• Radiopaque • Rounded, closed tip with eyelets • Smooth, polished surface inside and out • Centimeter markings on 8Fr sizes for precise depth placement • D oes not completely obstruct the ET tube and allows some space for ventilation using the SC15MM

Use optional adapter, item #SC15MM (see page 74), to ventilate while obtaining sample.

1 2 3 4 5 6 7 8 9 10

SC15MM

Connect to oxygen

*Sterile Endotracheal Tubes on pages 82-83.

ET TUBE ID

ET TUBE LENGTH MILA ET TUBE ITEM #

SIZE

LENGTH

ITEM # PP316 PP516 PP822 PP842

2.0mm

< 16.5cm

ETC20

use sampling catheter: 3.5Fr use sampling catheter: 5Fr use sampling catheter: 8Fr use sampling catheter: 8Fr

40cm (16in) 40cm (16in) 55cm (22in) 108cm (42in)

2.5-4.5mm 5.0-10.0mm

< 27cm

ETC25R-ETC45R ETC50R-ETC100R ETC1055, ETC1155

< 38.5cm

10.0-11.0mm < 57.5cm

Double Swivel ET Tube Adapter ******Fits all endotracheal tubes with 15mm connectors******

SC15MM

Transtracheal Technique: Medium to Large Dogs

Endoscopic Guided BAL: Small and Large Animal

Single lumen catheter with female luer lock for medication delivery and sampling at any site accessible by endoscope. To maintain sterility during advancement,these sets contain a water soluble plug in the distal end.

Catheter-over-needle insertion method. The semi-rigid flushing catheter has a stiffening stylet and luer adapter. The flushing catheter is packaged in a protective sleeve to allow aseptic handling (sterile gloves not required.)

TW1616 and TW1628

OD

LENGTH

SCOPE CHANNEL SIZE

ITEM # EDC190 EDC200 EDC220 EDC400

2.3mm 190cm (76in) 1.8mm 200cm (79in) 2.3mm 220cm (88in) 2.3mm 400cm (160in)

2.5mm 2.0mm 2.5mm 2.5mm

Stylet

Flushing/Sampling Catheter

Two and three lumen sampling catheters enable a sterile specimen retrieval via an endoscope. To maintain sterility during placement, the outer catheter has a glycol plug in the tip. Once in place, the inner catheter is advanced, pushing out the glycol plug, then further advanced for retrieval of the sterile specimen.

Introducer

MEDIUM/LARGE DOGS SIZE LENGTH

INTRODUCER

ITEM # TW1616 TW1628

16Ga 16Ga

41cm (16in) 70cm (28in)

14Ga 14Ga

TWO STAGE CATHETERS OD LENGTH 1.8mm 190cm (76in) 1.8mm 250cm (100in) TRIPLE STAGE CATHETERS OD LENGTH

SCOPE CHANNEL SIZE

ITEM #

2.0mm 2.0mm

EMAC700 EMAC700L

SCOPE CHANNEL SIZE

ITEM #

2.3mm 190cm (76in)

2.5mm

EMAC800

78

Made with FlippingBook Learn more on our blog