Amtech PCF Pre-Coat Feeder Series by Clean Air Industries

air pressure of the pulse valves. The PCF series comes in two models, The PCF- 60, which has a 60-gallon hopper, and the PCF-150, which has a 150-gallon hopper. 4.0 ELECTRICAL/MECHANICAL CONNECTIONS 4.1 PCF series installation is complete once the electrical power, compressed air, and discharge duct are connected. If the automatic feed feature of the unit is desired to be active, then an extra set of "normally open" contacts are necessary on the motor starter (for the blower) and the switch set to “Auto”.

4.1.1 Standard wiring for this unit is 115V AC. Wiring should be completed by an electrician, and in accordance with all applicable national, state, and local codes. Bring customer supplied 115V power to H,N & G on the terminal Strip. To run in Auto Mode, Amtech’s recommended operation mode, so that the feeder turns on and off with the dust collector, connect 1 and 2 to a normally open contact on the motor starter for the dust collector.

Page 6

sales@clean-air.com

www.clean-air.com

1-866-665-1829

Made with FlippingBook - professional solution for displaying marketing and sales documents online