Figure 1- Electrical Diagram

Figure 2- PCF Parts Diagram

4.1.2 The compressed air supply should be clean and free of oil and water. All PCF series models are equipped with an air pressure regulator with a 3/8” NPT female inlet, shown right. Plumbing should be completed by competent tradesmen in accordance with all applicable national, state, and local codes. Compressed Air should be set at 60 PSI for the PCF-60 and 90 PSI for the PCF-150.

4.1.3 The discharge duct, shown right, should be connected to the main duct leading to the inlet of the dust collector. The PCF-60 is equipped with a 4ӯ discharge duct. The PCF- 150 is equipped with a 6ӯ discharge duct. Any feeder should be located as close to the dust collector, as possible, to ensure good suction. Ductwork should be completed by