Filter Service - Promotions - June 2026

Which parameters can you measure & where can automation take over? Over 50 parameters on one photometer, 10 of them fully automated MACHEREY-NAGEL and Skalar: photometric expertise meets automation expertise

Brochure

The SP2000 handles the whole chain: dosing sample and pre-dosed reagents, capping, mixing, digestion, cooling, measurement and GLP-compliant calculation. The barcode scanner recognises the test, turbidity triggers a warning and out-of-range results are flagged. 10 parameters as robot tests with pre-dosed reagents No direct contact with hazardous chemicals

48 to 192 cuvettes capacity ; about 96 COD samples in 8 hours Automatic dilution when the measuring range is exceeded ST-COD to ISO 15705 and EPA 410.4 Data export to LIMS and spreadsheets , even during a running series

Removable sample and reagent racks for easy loading 2-year warranty with application-specific analysis protocols

Automated with the Skalar SP2000 These parameters are available as NANOCOLOR robot tests, with the manual range beside them for comparison. ®

Parameter

Robot range across all kits

Manual range across all kits

3 mg/L – 15 g/L O ₂ (7 kits)

2 mg/L – 60 g/L O ₂ (15 kits)

COD

0.04 – 40 mg/L NH ₄ -N (2 kits)

0.01 – 1600 mg/L NH ₄ -N (7 kits)

Ammonium

0.30 – 22.0 mg/L NO ₃ -N (2 kits) 0.003 – 4.0 mg/L NO ₂ -N (2 kits)

0.02 – 60 mg/L NO ₃ -N (5 kits)

Nitrate

0.002 – 4.0 mg/L NO ₂ -N (3 kits)

Nitrite

Total nitrogen TNb

0.5 – 220 mg/L N (2 kits)

0.5 – 220 mg/L N (3 kits)

ortho-Phosphate

0.05 – 15.00 mg/L P (2 kits)

0.010 – 50 mg/L P (8 kits)

total Phosphate

0.05 – 15.00 mg/L P (3 kits)

0.010 – 50 mg/L P (8 kits)

0.5 – 200 mg/L Cl ⁻ (2 kits)

0.2 – 1000 mg/L Cl ⁻ (3 kits)

Chloride

0.05 – 3.00 mg/L S² ⁻ (1 kit)

0.01 – 3.0 mg/L S² ⁻ (1 kit)

Sulfide

Phenolic index

0.2 – 5.0 mg/L phenol (1 kit)

0.01 – 7.0 mg/L phenol (2 kits)

30 – 3000 mg/L CH ₃ COOH (1 kit)

30 – 3000 mg/L CH ₃ COOH (1 kit)

Organic acids

Other parameters available for manual processing

Type

Parameters

BOD ₅

Sum parameters

- TOC

- AOX

(0.5 – 3000 mg/L O ₂ , 2 kits)

(2.0 – 300 mg/L C, 2 kits)

(0.1 – 3.0 mg/L, 1 kit)

Nitrogen

Kjeldahl nitrogen TKN (1.0 – 16 mg/L TKN, 1 kit)

Aluminium

- Cadmium

- Chromate and total chromium

Cobalt

(0.01 – 1.00 mg/L Al³ ⁺ , 2 kits)

(0.002 – 2.00 mg/L Cd² ⁺ , 2 kits)

(0.005 – 3.0 mg/L Cr, 3 kits)

(0.002 –

- Copper

- Iron

- Lead

Manganese

0.70 mg/L Co² ⁺ , 1 kit)

(0.01 – 10.0 mg/L Cu² ⁺ , 2 kits)

(0.005 – 5.00 mg/L Pb² ⁺ , 2 kits)

(0.005 – 15.0 mg/L Fe, 3 kits)

(0.005 – 10.0 mg/L Mn, 3

Metals

- Molybdenum

- Nickel

- Silver

- Tin

(0.01 – 10.0 mg/L Ni² ⁺ , 2 kits)

(0.08 – 3.00 mg/L Ag ⁺ , 1 kit)

kits)

(1.0 – 40.0 mg/L Mo, 1 kit)

(0.10 – 3.00 mg/L Sn, 1 kit)

Zinc

- Zirconium

(0.02 – 6.00 mg/L Zn² ⁺ , 2 kits)

(5 – 100 mg/L Zr, 1 kit)

Chlorine Peroxide

- Chlorine dioxide

- Ozone

(0.02 – 10.0 mg/L Cl ₂ , 2 kits)

(0.04 – 5.00 mg/L ClO ₂ , 2 kits)

(0.01 – 2.00 mg/L O ₃ , 2 kits)

Disinfection and oxidants

- Hydrazine

- DEHA

(0.03 – 2.00 mg/L H ₂ O ₂ , 1 kit)

(0.002 – 1.50 mg/L N ₂ H ₄ , 1 kit)

(0.05 – 1.00 mg/L, 1 kit)

Sulfate

- Sulfite

- Fluoride

- Cyanide

(20 – 1000 mg/L SO ₄ ² ⁻ , 3 kits)

(5 – 100 mg/L SO ₃ ² ⁻ , 1 kit)

(0.05 – 2.00 mg/L F ⁻ , 2 kits)

(0.001 – 0.80 mg/L CN ⁻ , 3 kits)

Salts and hardness

Thiocyanate

- Silica

- Potassium

(0.5 – 50.0 mg/L SCN ⁻ , 1 kit)

(2 – 50 mg/L K ⁺ , 1 kit)

(0.002 – 10.00 mg/L Si, 1 kit)

Hardness, total, Ca/Mg, carbonate and residual (0.03 – 25.0 °e, 4 kits)

Formaldehyde

- Methanol

- Ethanol

- Hydrocarbons

(0.1 – 10.0 mg/L HCHO, 2 kits)

(0.2 – 15.0 mg/L, 1 kit)

(0.10 – 1.00 g/L, 1 kit)

(0.5 – 5.6 mg/L, 1 kit)

Organics and industry

POC ionic

- Starch

- Complexing agents

- Surfactants, anionic, cationic and non-

(20 – 200 mg/L, 1 kit)

(5 – 100 mg/L, 1 kit)

(0.5 – 10.0 mg/L IBiK, 1 kit)

- Vicinal diketones

- Bitter units

(0.02 – 15.0 mg/L, 5 kits)

(0.015 – 0.600 mg/kg, 1 kit)

(2.0 – 80.0 BE, 1 kit)

pH

Oxygen

- Turbidity

- Colour

- SAC

(0.5 – 12.0 mg/L O ₂ , 1 kit)

(6.5 – 8.2, 1 kit) -

(1 – 1000 NTU, 2 kits)

(5 – 500 mg/L Pt, 1 kit)

(0.1 – 150.0 1/m, 1 kit)

Physical and process

Sludge activity TTC (5 – 150 µg TPF, 1 kit)

Contact your representative for more information!

Filter Service end-of-year promotions

Water analysis

26