Fire Chief FC2500 Furnace Operator Manual

CAUSES RESTRICTION

Proper installation

improper installation

o Maximum unsupported horizontal length: 3 feet (1 m); o Galvanized flue pipes must not be used because the coatings vaporize at high temperatures and release dangerous gases; o Flue pipes must be at least 24 gauge in thickness; o The chimney connector must be in good condition; o Flue pipe joints should overlap 1 1/4". (30 mm); o Straight up installations need to have either a connector where one end has no fastener or a telescopic/adjustable length; o Removal of the assembly for cleaning should not require that the furnace be moved; o The male ends of the sections must be oriented towards the appliance so that falling dust and condensation stay inside the pipe; o A straight flue pipe assembly offers the least restriction to gas flow and results in stronger draft. Straight assemblies also need less maintenance as there are is less restrictions from corners to collect creosote; o The use of 45° elbows is strongly recommended; o Elbow added resistance is equivalent to : a 90° elbow = 5’ (152 cm), a 45° elbow = 2.5’ (76 cm); o Never use more than two 90° elbows.