FC2500 Furnace Installation and Operation Manual
13.2Appliance performance (1) Fuel type
Dry cordwood
Recommended heating area [*]
1,000 to 2,500 ft² (93 à 232 m²)
Firebox volume
3.6 ft³ (0.102 m³)
Maximum burn time [*]
10 h
Maximum input capacity (dry cordwood) (2) Overall heat output rate (min. to max.) (3)
310,000 BTU
21 742 BTU/h to 62 107 BTU/h (6.37 kW to 18.2 kW)
Average overall efficiency (4)
78% (HHV) (5)
Delivered heat output rate (min. to max.) (7)
19 851 BTU/h to 64 073 BTU/h (5.82 kW to 18.8 kW)
Average delivered efficiency (8)
77% (HHV) (5)
Optimum efficiency (9)
79.0%
Category I - 0.086 lb/mm BTU Category II - 0.090 lb/mm BTU Category III - 0.090 lb/mm BTU Category IV - 0.12 lb/mm BTU
Average particulate emissions rate (10)(11)
Average CO (12)
1.3 g/min
Average electrical power consumption (13) 330 W [*] Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors, climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat distribution systems have a significant impact in making heat circulation optimum. (1) Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with a moisture content between 18% and 28%. (2) Input value at 10lb/ft³ fuel loading density and dry energy value of 8,600BTU/lb. (3) Overall: Radiated and delivered heat together at10lb/ft³ fuel loading density over one total burn cycle. (4) Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand. (5) Higher Heating Value of the fuel. (6) Lower Heating Value of the fuel. (7) Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle. (8) Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand. (9) Optimum overall efficiency at a specific burn rate (LHV). (10) Based on delivered heat output. (11) This appliance is officially tested and certified by an independent agency. (12) Carbon Monoxide. Based on overall heat output at 10lb/ft³ fuel loading density. (13) Unless stated otherwise, measures were taken directly at the main power source and include all electrical components present in the appliance.
85
Made with FlippingBook - professional solution for displaying marketing and sales documents online