Terminal strip for heating/cooling manifold VOORL for 5 or 8 room thermostats
Technical data
Application
Surface finish: Housing colour: Housing material: Operating voltage:
matt
This device is specifically designed for fixed wiring of 230 VAC single- room temperature controllers and the associated valve actuators for fixed-location attachment. Switching between heating/cooling is performed via a central contact. Max. number of terminal strips: num- ber of channels x4, 2 per channel, channel 1 and 2, as well as 5 and 6 combinable, random relationship between channels and rooms The devices VOORx-318.053 and VOORx-215.053 have a an integrated pump function.
light grey, like RAL 7035
ABS plastic
230 VAC, 50 Hz −10 … +50 °C −20 … +70 °C
Ambient temperature: Storage temperature: Permissible atmospheric humidity: Electrical connection:
max. 95% rel. humidity, non-con- densing spring-cage terminals 0.2 mm² to 1.5 mm²; if end sleeves are used, 0.25 mm² to 0.75 mm²
Connectable pump capacity: Hardware protection: Mounting/attachment:
max. 180 VA
T3,15/250 V, Ø 5 x 20 mm
Surface-/wall-mounting by means of screws on a wall or magnetic feet on magnetic underground
Protection rating: Protection class:
IP 20
II, if properly mounted
Accessories:
optional magnetic fastening set for simple installation in heating mani- fold: JZ-24
Type/image
Item no.
Features
PG
VOORL-215.009
General features: Terminal strip in housing for wiring up to 5 room thermostats and up to 20 actuators; up to 4 actuators per channel can be connected
DA490110
I
Max. switching current: output 1–5: 3 (1) A Total of all the outputs (5 channels): 3 (1) A Switching power: total of 920 W
ECO contact: if clock regulators are used, a master-slave time zones can be defined; and can be switched to ECO function via an external switching contact on terminal U Control function: Heating or cooling
VOORL-215.053
DA490310
As for VOORL-215.009, but including pump module (max. 0.75 A)
I
VOORL-318.009
General features: Terminal strip in housing for wiring up to 8 room thermostats and up to 32 actuators; up to 4 actuators per channel can be connected Max. switching current: output 1–8: 3 (1) A Total of all the outputs (8 channels): 3 (1) A Switching power: Total of 1380 W ECO contact: if clock regulators are used, a master-slave time zones can be defined; and can be switched to ECO function via an
DA490010
I
external switching contact on terminal U Control function: Heating or cooling
VOORL-318.053
DA490210
As for VOORL-318.009, but including pump module (max. 0.75 A)
I
Accessories
Item no.
Features
PG
JZ-24
BN990002
Magnetic fastening set for simple and safe fastening of the multi-channel receiver and VOORL terminal strips on a metallic substrate (for example, heating manifold)
II