Mechanical room temperature controller, FTR Flush-mounted installation – Design Berlin UP
Type/image
Item no.
Features
Circuit diagram
PG
FTR 101.052#21
General features: “Auxiliary heating” display; mechanical range limitation; auxiliary heating switch; external setting Operating voltage: 230 VAC, 50 Hz Max. switching current: the total current (heating + auxiliary heating) may not exceed 10 (4) A Max. switching voltage: 230 VAC, 50 Hz Min. switching voltage: 230 VAC, 50 Hz Switching power: the total power output (heating + auxiliary heating) may not exceed 2300 W Switching contact: NC contact (max. 10 actuators) Control function: Heating Scope of delivery: controller, alre frame “Berlin” (neutral), cover 50 x 50 mm, pure white (like RAL 9010), glossy General features: ECO function; “heating” display ; mechanical range limitation; “on/off” switch; external setting; protective cap; VDE-tested
UA010702
I
FTR 101.062#00
UA010811
I
Operating voltage: 230 VAC, 50 Hz Max. switching current: 10 (4) A
Max. switching voltage: 230 VAC, 50 Hz Min. switching voltage: 230 VAC, 50 Hz Switching power: 2300 W Switching contact: NC contact (max. 10 actuators) Control function: Heating Input “temperature reduction”: Approx. 4 K (230 VAC, 50 Hz) Cover sets are offered in various designs (see the separate over- view, “alre flush-mounted range (cover sets)”) and are not included in the delivery. Suitable set no: JZ-002.xxx, (see page 82/83) e.g.: cover set 50 x 50 mm, pure white, glossy: JZ-002.000 cover set 55 x 55 mm, pure white, glossy: JZ-002.100 BUSCH-JAEGER cover set Reflex SI/SI Linear, pure white, glossy: JZ-002.200 / BJ General features: Climate controller for 2-pipe systems, mechanical range limitation; “heating/off/cooling” switch;
FTR 101.063#00
UA011000
I
external adjustment; protective cap Operating voltage: 230 VAC, 50 Hz Max. switching current: 5 (2) A
Max. switching voltage: 230 VAC, 50 Hz Min. switching voltage: 230 VAC, 50 Hz Switching power: 1150 W Switching contact: changeover switch (max. 5 actuators) Control function: Heating or cooling For cover sets see the separate overview “alre flush-mounted range (cover sets)”, not included in the delivery. Suitable set no: JZ-012.xxx, (see page 82/83) e.g.: cover set 50 x 50 mm, pure white, glossy: JZ-012.000 cover set 55 x 55 mm, pure white, glossy: JZ-012.100 General features: Climate controller for 2-pipe systems, espe- cially heat pumps; mechanical range limitation; “heating/cool- ing” switch; external setting; protective cap Operating voltage: 230 VAC, 50 Hz Max. switching current: 5 (2) A Max. switching voltage: 230 VAC, 50 Hz Min. switching voltage: 230 VAC, 50 Hz Switching power: 1150 W Switching contact: changeover switch (toggler, max. 5 actuators) Control function: Heating or cooling Cover sets are offered in various designs (see the separate over- view, “alre flush-mounted range (cover sets)”) and are not included in the delivery. Suitable set no: JZ-004.xxx, (see page 82/83) e.g.: cover set 50 x 50 mm, pure white, glossy: JZ-004.000 cover set 55 x 55 mm, pure white, glossy: JZ-004.100
FTR 101.065#00
UA010910
I
Catalogue 2022 | Page 78