New Products: Link Clamps

5000 PSI Twin Lever Link Clamp High Pressure Offset Output Curves VEKTEK 5000 PSI INCH TWIN LEVER LINK CLAMP CLAMPING FORCE OUTPU T CURVES

16-X215-20

16-X215-20

Non-Usable Range

Non-Usable Range

1000 1200 1400 1600

Clamping Force (LBS) Lever Length "L" (IN)

Operating Cy Pressure Force linder

Min Lever

gth

Len

L = .88

0.88 1.00 1.18 1.30 1.50 1.75 2.25 3.00 "L" (IN)

(PSI) 5000 4500 4000 3500 3000 2500 2000 1500 1000 500

(LBS)

1370 2112 1547 1104 927 732 579 409 284 1.18 1233 1901 1393 994 835 659 521 368 255 1.18 1096 1690 1238 884 742 586 463 327 227 1.00 959 1478 1083 773 649 512 406 286 199 0.88 822 1267 928 663 556 439 348 245 170 0.88 685 1056 774 552 464 366 290 204 142 0.88

L = 1.75 L = 2.25 L = 3.00 L = 1.30 L = 1.50 L = 1.18

L = 1.00

0 200 400 600 800

548 411 274 137

845 619 442 371 293 232 164 113 0.88 634 464 331 278 220 174 123 85 0.88 422 309 221 185 146 116 82 57 0.88 211 155 110 93 73 58 41 28 0.88 3500 4210 5000 5000 5000 5000 5000 5000

Max Operating Pressure (PSI)

0

1000 2000 3000 4000 5000 Operating Pressure (PSI)

ILS916019-15 REV A

VEKTEK 5000 PSI INCH TWIN LEVER LINK CLAMP CLAMPING FORCE OUTPUT CURVES ILS916019-15 REV A

16-X218-20

16-X218-20

Non-Usable Range

Operating Cy Pressure Force - The tables and graphs show the relationship between lever length, operating pressure and clamping force. - The lever lengths shown in red bold are Vektek's available levers for purchase. See page XXXX for details. - The row across the bottom of the table is the maximum operation pressure allowed for the associated lever length. - The column on the right of the table is the minimum lever length allowed at the associated operation pressure. - Using the clamp in the Non-Usable range will damage clamp and void product warranty. Min Lever linder Len gth (PSI) 5000 4500 4000 (LBS) 1.10 1.25 1.48 1.75 2.00 2.50 3.00 4.00 "L" (IN) 1972 3417 2453 1712 1264 1017 732 571 397 1.97 1775 3075 2207 1541 1137 916 659 514 358 1.75 1578 2734 1962 1370 1011 814 585 457 318 1.57 1380 2392 1717 1198 885 712 512 400 278 1.44 Clamping Force (LBS) Lever Length "L" (IN) 1200 1600 2000 2400 L = 1.10 L = 1.25

Non-Usable Range

L = 1.48

3500 3000 2500 2000 1500 1000 500

L = 2.50 L = 3.00 L = 4.00 L = 2.00 L = 1.75

1183 2050 1472 1027 758 610 439 343 238 1.44 986 1709 1226 856 632 509 366 286 199 1.44 789 1367 981 685 506 407 293 229 159 1.44 592 1025 736 514 379 305 220 171 119 1.44

800

394 197

683 491 342 253 203 146 114 79 1.44 342 245 171 126 102 73 57 40 1.44 3350 4100 5000 5000 5000 5000 5000 5000

400

Max Operating Pressure (PSI)

0

0 1000 2000 3000 4000 5000 Operating Pressure (PSI)

ILS916019-18 REV A ILS916019-18 REV A VEKTEK 5000 PSI INCH TWIN LEVER LINK CLAMP CLAMPING FORCE OUTPUT CURVES

16-X222-20

- The tables and graphs show the relationship between lever length, operating pressure and clamping force. - The lever lengths shown in red bold are Vektek's available levers for purchase. See page XXXX for details. - The row across the bottom of the table is the maximum operation pressure allowed for the associated lever length. - The column on the right of the table is the minimum lever length allowed at the associated operation pressure. - Using the clamp in the Non-Usable range will damage clamp and void product warranty. Operating Cy Min Lever linder Len Force Pr ssur gth (PSI) (LBS) 1.30 1.50 1.73 2.00 2.38 3.00 4.00 5.00 "L" (IN) 5000 3081 4953 3482 2595 1998 1509 1079 739 562 2.29 4500 2773 4458 3133 2335 1798 1358 971 665 505 2.04 4000 2465 3962 2785 2076 1598 1207 863 591 449 1.85 3500 2157 3467 2437 1816 1398 1056 755 517 393 1.75 Non-Usable Range Clamping Force (LBS) Lever Length "L" (IN) 2000 2500 3000 3500 16-X222-20 L = 1.30 L = 1.50

Non-Usable Range

L = 1.73

L = 4.00 L = 5.00 L = 3.00 L = 2.38 L = 2.00

3000 2500 2000 1500 1000 500

1849 2972 2089 1557 1199 905 647 443 337 1.75 1541 2476 1741 1297 999 755 539 369 281 1.75 1233 1981 1393 1038 799 604 431 295 225 1.75 924 1486 1044 778 599 453 324 222 168 1.75

1500

1000

616 308

991 696 519 400 302 216 148 112 1.75 495 348 259 200 151 108 74 56 1.75 3480 4300 5000 5000 5000 5000 5000 5000

500

Max Operating Pressure (PSI)

0

0

1000 2000 3000 4000 5000 Operating Pressure (PSI)

ILS916019-22 REV A

ILS916019-22 REV A

- The tables and graphs show the relationship between lever length, operating pressure and clamping force. - The lever lengths shown in red bold are Vektek's available levers for purchase. See page P-2 for details. - The row across the bottom of the table is the maximum operation pressure allowed for the associated lever length. - The column on the right of the table is the minimum lever length allowed at the associated operation pressure. - Using the clamp in the Non-Usable range will damage clamp and void product warranty.

- The tables and graphs show the relationship between lever length, operating pressure and clamping force. - The lever lengths shown in red bold are Vektek’s available levers for purchase. See previous page for details. - The row across the bottom of the table is the maximum operation pressure allowed for the associated lever length. - The column on the right of the table is the minimum lever length allowed at the associated operation pressure. - Using the clamp in the Non-Usable range will damage clamp and void product warranty.

Made with FlippingBook - Online Brochure Maker