New Products: Work Supports

ALL NEW WORK SUPPORT TECHNOLOGY High Capacity / Smallest Size. ALL NEW WORK SUPPORT TECHNOLOGY High Capacity / Smallest Size.

C R E AT I N G N E W E X P E C T AT I O N S

ALL NEW WORK SUPPORT TECHNOLOGY High Capacity / Smallest Size

1000# Capacity 3/4”

Threaded Cartridge

ALSO AVAILABLE WITH THE NEW TECHNOLOGY TUFFGRIP™ PART PRESENT SENSING WORK SUPPORTS

AIR SENSING CONTROL KIT

www.vektek.com

Now up to 3X competitive capacity at 5,000 PSI! Plungers stay retracted during part loading. Hydraulic pressure advances the plunger exerting only spring force as it makes contact with the part. Hydraulic pressure then automatically sequences, “freezing” the plunger, to properly support the part.  Available in 1000, 2000, 4000 & 8000 lb. capacity.  Order with base or cartridge only.  Ventless configuration and built in wipers protect the plunger movement from chips and debris.  Four bolt base is compatible with Vektek In-Port flow control and In-Port sequence valves.  Uses Vektek’s BHC technology to guard against corrosion. n O-ring face seal design makes machining cavities easier. NEW World’s Smallest Work Supports!

TUFFGRIP™ WORK SUPPORTS HIGH CAPACITY

Actual Size 1,000 lbs Capacity

3/4” Threaded Body

Standard SAE porting and alternate o-ring manifold face seal is located in the base of the support for bolt down installation. The base can be removed for direct cartridge mounting.

ILS100718 REV D U.S. PATENT NO. 10,799,992

Contact Force (lbs)

Base Dimensions (in.)

Retracted Height (in.)

Working Oil Capacity (cu. in.) **

Port X Depth for Optional In-Port Valves****

Model No.

Support Capacity (lbs)*

Mounting Style***

Stroke (in.)

Fluid Advance Work Supports, hydraulic pressure pushes a spring which lifts plunger, hydraulic pressure locks in place. 10-0704-10 1000 Cartridge 0.5-4 0.25 N/A 1.63 0.03

N/A

10-0804-20 10-0706-10 10-0806-20 10-0706-16 10-0806-26 10-0708-10 10-0808-20 10-0708-16 10-0808-26 10-0710-10 10-0810-20

SAE/Manifold

1 X 1 X 1

2.25 2.14 2.79 2.64 3.29 2.85 3.50 3.35 4.00 4.00 4.63

SAE 4 X 0.58

Cartridge

N/A

N/A

0.25

0.05

SAE/Manifold

1.19 X 1.31 X 1.31

SAE 4 X 0.58

2000

1-6

Cartridge

N/A

N/A

0.50

0.07

SAE/Manifold

1.19 X 1.31 X 1.31

SAE 4 X 0.58

Cartridge

N/A

N/A

0.25

0.20

SAE/Manifold

1.50 X 1.63 X 1.63

SAE 4 X 0.58

4000

3-10

Cartridge

N/A

N/A

0.50

0.23

SAE/Manifold

1.50 X 1.63 X 1.63

SAE 4 X 0.58

Cartridge

N/A

N/A

8000

4-13

0.625

0.57

SAE/Manifold

1.63 X 2.13 X 2.13

SAE 4 X 0.75

* Support capacities are listed at 5,000 psi maximum pressure. Support capacities for other pressures are shown in the fluid advance High Capacity and Part Present Sensing load capacity chart ** Restrict flow rate to a maximum of 130 cu. in./minute. *** For cartridge mount models, see cavity dimensions drawings in this catalog section. **** In-Port Valves require the use of manifold mount ports. NOTE: The maximum system back-pressure a fluid advance work support can overcome is 10 psi. Returning back-pressure greater than 10 psi may cause slow or failed retractation.

www.vektek.com

TUFFGRIP™ WORK SUPPORTS HIGH CAPACITY NEW

Plungers stay retracted during part loading while air flow travels through the work support. Hydraulic pressure advances the plunger exerting only spring force as it makes contact with the part. This closes the integral air valve to indicate part is present and contacted. Hydraulic pressure then automatically sequences, “freezing” the plunger.  Available in 2,000, 4,000 and 8,000 lb. capacity.  Order with four bolt base or cartridge only.  Once support is locked, air sensing positively confirms both contact and part present.  Use Vektek’s Air Sensing Control Kit 50-8240-00 for easy setup.  Four bolt base is compatible with Vektek In-Port flow control and In-Port sequence valves.  Uses Vektek’s BHC technology to guard against corrosion. n O-Ring face seal design makes machining cavities easier. n Max air operating pressure is 15 PSI. Standard SAE porting and alternate O-Ring manifold face seal is located in the base of the support for bolt down installation. The base can be removed for direct cartridge mounting. Confirm part is present and contacted even on as-cast surfaces!

Patented

PART PRESENT SENSING WORK SUPPORT AIR FLOW

Workpiece

POPPET CLOSED & AIR PRESSURE BUILDS

POPPET OPEN & AIR VENTS UNDER CONTACT BOLT

ILS100723 REV A

WORK SUPPORT ADVANCES

OIL FEED HOLE

AIR FEED HOLE

Support Capacity (lbs)*

Contact Force (lbs)

Base Dimensions (in.)

Retracted Height (in.)

Port X Depth for Optional In-Port Valves****

Model No.

Mounting Style***

Stroke (in.)

Oil Capacity (cu. in.)**

Fluid Advance Work Supports, hydraulic pressure pushes a spring which lifts plunger, hydraulic pressure locks in place. 10-0706-10-PS 2000 Cartridge 1-6 0.25 N/A 2.28 0.05 10-0806-20-PS SAE/Manifold 1.19 X 1.31 X 1.31 2.93

N/A

SAE 4 X 0.58

10-0706-16-PS 10-0806-26-PS 10-0708-10-PS 10-0808-20-PS 10-0708-16-PS 10-0808-26-PS 10-0710-10-PS 10-0810-20-PS

Cartridge

N/A

2.78

N/A

0.50

0.07

SAE/Manifold

1.19 X 1.31 X 1.31 3.43

SAE 4 X 0.58

Cartridge

N/A

3.04

N/A

0.25

0.20

SAE/Manifold

1.50 X 1.63 X 1.63 3.69

SAE 4 X 0.58

4000

3-10

Cartridge

N/A

3.54

N/A

0.50

0.23

SAE/Manifold

1.50 X 1.63 X 1.63 4.19

SAE 4 X 0.58

Cartridge

N/A

4.28

N/A

8000

4-13

0.63

0.57

SAE/Manifold

1.63 X 2.13 X 2.13 4.91

SAE 4 X 0.750

NOTE: The maximum system back-pressure a fluid advance work support can overcome is 10 psi. Returning back-pressure greater than 10 psi may cause slow or failed retractation. * Support capacities are listed at 5,000 psi maximum pressure. Support capacities for other pressures are shown in the fluid advance High Capacity and Part Present Sensing load capacity chart. ** Restrict flow rate to a maximum of 130 cu. in./minute. *** For cartridge mount models, see cavity dimensions drawings in this catalog section. **** In-Port Valves require the use of manifold mount ports.

1334 E. 6th Avenue Emporia, KS 66801

NEW! Air Sensing Control Kit for

Pneumatic Confirmation Systems

 Adjustable air pressure and flow gives you the ability to monitor most confirmation valves, part present or clamp position systems.  Easy electronic pressure switch adjustment with 2 PNP* digital set points and 1 analog output to meet your specific needs.  Can be used with Pallet Decouplers, Pneumatic Confirmation Valves, Part Present Sensing Work Supports or self-made part location orifices.  Ready-to-use kit with everything you need to feed back a confirmation signal of your choice!

FLOW CONTROL

PRESSURE SWITCH M12, 5 PIN MALE CONNECTION

PRESSURE REGULATOR

1/4 NPT FEMALE INPUT

8.56

2X .281

M12 CABLE 16.4 FT

SAE 6 MALE OUTPUT 1/4 NPT WITHOUT ADAPTER

4.00

2X .50

3.26

7.25

PRESSURE GAUGE 0-30 PSI

AIR HOSE, 15 FT

ILS508000 REV A

Air Sensing Control Kit

AIR FILTER AUTOMATIC DRAIN

Operating Pressure Range (psi)

Max Air Flow Rate (SCFM)

Max Air Pressure (psi)

Filtration Element (micron)

Power Supply (VDC)

Power Consumption (mA)

Model No.

2 Digital Contacts

1 Analog Output

50-8240-00

200

0-25

12

5

15-32

50

N/O or N/C 0-10V or 4-20 mA

www.vektek.com

* For NPN applications order signal converter cable 27-84200-00.

Page 1 Page 2 Page 3 Page 4

www.vektek.com

Made with FlippingBook - Online Brochure Maker