SMW-electronics_Broschuere_EN

F180 Ethernet

Inductive Coupling System

■ Stationary Unit - Base ■ Mobile Unit - Remote

Axial coupler

Base:

Base / Remote:

Base / Remote:

C

H

C

H

H 1

H 1

Remote:

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupling system F180 Ethernet

Base

Remote

Type Id. No.

0E011246

0E011247

A B

mm mm mm mm mm mm mm mm mm

180

85 93

B1

C D

29.5

57 20

E F

5

H

34

H1

7

ɑ

60 Al, GFK IP67

degree

Housing material Protection class

Function Base LED Power Color

Function Remote LED Actuator Color

Green / red

Green / red

Off » Unit not supplied with voltage (or undervoltage) On (green) » Voltage ok and mobile unit has been detected 2 Hz green 50/ 50% » Operating temperature in critical range 1 Hz green 25/75% » Voltage ok but no mobile unit detected 1 Hz red / green » Incompatible mobile unit detected 2 Hz red » Foreign element detected 5 Hz red » Internal error

Off » Unit not paired On (green) » Unit paired, voltage output actuator ok Flashes 2 Hz red » Unit paired but short circuit on actuator Flashes 5 Hz red » Internal error

Function

Function

LED Sensor supply Color

Green / red

Off » Unit not paired On (green) » Unit paired, voltage output sensor (24 V) ok Flashes 2 Hz red » Unit paired but short circuit on sensor (24 V) Flashes 5 Hz red » Internal error

LED Signal transmission Ethernet Color Yellow / red

Function

Off » No mobile unit detected On / yellow » Signal transmission ready 1 Hz yellow » Data packets are being transmitted 3 Hz yellow » 50% of the transmission bandwidth used (10 s) 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)

LED Signal transmission Color Yellow / red

Function

Off » No mobile unit detected On / yellow » Signal transmission ready

Flashes 1 Hz yellow » Data packets are being transmitted Flashes 3 Hz yellow » 50% of the transmission bandwidth used (10 s) Flashes 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)

LED Energy transmission Color Yellow / red

Function

Off » No mobile unit detected On (yellow) » Unit coupled, voltage output ok

1 Hz red / yellow » Short circuit at voltage output sensor 3 Hz red / yellow » Short circuit at voltage output actuator 3 Hz red » Short circuit at both voltage outputs 5 Hz red » Internal error

Function

SMW-electronics 15