F60-4 / 4A
Inductive Coupling System
■ Stationary unit - Base ■ Mobile unit - Remote
Axial coupler
Base:
Remote:
A
A
C1
C1
A
C
B
B
1
1
ØD
ØD
ØD
C
C
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F60-4/4A
Base
Remote
Type Id. No.
0E010972
0E010973
A B C
mm mm mm mm mm mm
60
51 14
-
12
C1
13 36
D
D1
64
-
Housing material Protection class Operating temperature
POM, PA66, PC GF 30% IP67 0° C ... +60° C -10° C ... +70° C 0 mm ... 3 mm
Storage temperature Transmission distance Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid Output Ready delay
24 V ± 10% DC
-
-
24 V ± 10% DC
< 300 mA
-
-
< 100 mA
-
< 200 mV
- -
0 / 24 V
≤ 100 ms
SMW-electronics 21