SMW-electronics_Broschuere_EN

F60-4 / 4A

Inductive Coupling System

■ Stationary unit - Base ■ Mobile unit - Remote

Axial coupler

Base:

Remote:

A

A

C1

C1

A

C

B

B

1

1

ØD

ØD

ØD

C

C

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupling system F60-4/4A

Base

Remote

Type Id. No.

0E010972

0E010973

A B C

mm mm mm mm mm mm

60

51 14

-

12

C1

13 36

D

D1

64

-

Housing material Protection class Operating temperature

POM, PA66, PC GF 30% IP67 0° C ... +60° C -10° C ... +70° C 0 mm ... 3 mm

Storage temperature Transmission distance Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid Output Ready delay

24 V ± 10% DC

-

-

24 V ± 10% DC

< 300 mA

-

-

< 100 mA

-

< 200 mV

- -

0 / 24 V

≤ 100 ms

SMW-electronics 21