M30-2
Inductive Coupling System
Application/customer benefits • Contact free, safe transmission of energy and signals between moving / rotating and stationary components • Application examples: Supply of sensors, supply and monitoring of remote systems, contactless battery charge (W-Charge), monitoring of door contacting, valve control, plug replacement • Dynamic Pairing • Wear and maintenance free • Protective functions: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Mounting M30 x 1.5 • Operating voltage 24 V (18 ... 30 V) • Transmission distance 0 - 8 mm ■ Contact free transmission of energy and signals
Axial coupler
• Transmission of energy: 24 V / 12 W (500 mA) • Transmission of signals: 2 digital signals (PNP) • Connection: Remote female connector M12x1 (5-pin), base male connector M12x1 (4-pin) • Protection class IP 67 • Id. No. Base: 0E011600, Id. No. Remote: 0E011601
Block diagram:
PLC
24 V/12 W
Energy
2 digital signals
0 - 8 mm
Base
Remote
Signals
Subject to technical changes. For more detailed information please ask our customer service.
Function Base LED Power Color
Function Remote LED Coupling Color
Green / red
Green / red
Off » Unit not supplied with voltage (or undervoltage) On (green) » 24 V ok and remote unit has been detected Flashes 2 Hz green » 24 V ok but no remote unit detected Flashes 1 Hz green / red » Incompatible remote unit detected Flashes 2 Hz red » Foreign object detected Flashes 5 Hz red » Internal error
Off » Unit is not connected On (green) » Unit is connected, voltage output DC 24 V ok Flashes 2 Hz red » Unit is connected but short circuit at DC 24 V Flashes 5 Hz red » Internal error
Function
Function
LED Signal 1 Color
Yellow
LED Signal 1 Color
Off » Digital input 1 is not connected On » Digital input 1 is connected
Function
Yellow
LED Signal 2 Color
Off » Digital input 1 is not connected or no remote unit detected On » Digital input 1 is connected Flashes 2 Hz » Digital input connected but short circuit at the output Flashes 5 Hz » Overload voltage output remote unit
Yellow
Off » Digital input 2 is not connected On » Digital input 2 is connected
Function
Function
LED Signal 2 Color
Yellow
Out » Digital input 2 is not connected or no remote unit detected On » Digital input 2 is connected Flashes 2 Hz » Digital input connected but short circuit at the output Flashes 5 Hz » Overload voltage output remote unit
Function
30 SMW-electronics