SMW-electronics_Broschüre_EN

M30-IOL

Inductive Coupling Sytem

■ Contact free transmission of energy and signals

Axial coupler

Application/customer benefits • Contact free, safe transmission of energy and signals between moving / rotating and stationary components • Application examples: Supply of sensors, Supply and monitoring of remote systems • Dynamic Pairing • Wear and maintenance free • Protective function: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility

Technical features • Mounting M30 x 1.5

• Operating voltage 24 V (18 ... 30 V) • Transmission distance 0 - 10 mm

• Transmission of energy: 24 V / 12 W (500 mA) with a distance of 0 - 7 mm • Transmission of signals: IO-Link (COM1, COM2, COM3), 1 digital signal • Connection: Base male connector M12 (5-pin), remote female connector M12 (4-pin) • Protection class IP 67 • Id. No. Base: 0E011604, Id. No. Remote: 0E011605

Block diagram:

IO-Link Master

24 V/12 W (12 W with a distance of 0 - 7 mm)

Energy

IO-Link-Device

0 - 10 mm

Base

Remote

Signals

IO-Link COM1, COM2, COM3

Subject to technical changes. For more detailed information please ask our customer service.

Function Base LED Power Color

Function Remote LED Power Color

Green / red

Green / red

Off » Unit not supplied with voltage (or undervoltage) On (green) » 24 V ok and mobile unit has been detected Flashes 2 Hz green » 24 V ok but no mobile unit detected Flashes 1 Hz red / green » Incompatible mobile unit detected Flashes 2 Hz red » Foreign object detected Flashes 5 Hz red » Internal error Flashes 5 Hz green » Voltage oscillating circuit out of the permissible range Flashes 0.5 Hz green » 24 Vin out of the permissible range

Off » Unit is not coupled On (green) » Unit coupled, voltage output DC 24 V ok Flashes 2 Hz red » Connected but short-circuit at DC 24 V Flashes 5 Hz red » Internal error

Function

Function

LED IO-Link Color

Yellow / red

Off » No stationary unit detected Flashes 1 Hz on 100 ms off yellow » IO-Link in IO-Link mode On yellow » Devices coupled, no IO-Link mode Flashes 2 Hz yellow » IO-Link in SIO mode or no IOL-Device detected

LED IO-Link Color

Function

Yellow / red

Off » No mobile unit detected Flashes 1 Hz on 100 ms off yellow » IO-Link in IO-Link mode On (yellow) » Devices coupled, no IO-Link mode Flashes 2 Hz yellow » IO-Link in SIO mode or no IOL-device detected Flashes 2 Hz red » Short-circuit at IO-Link PIN Flashes 5 Hz red » Overload 24V voltage output mobile unit

Flashes 2 Hz red » Short-circuit at IO-Link PIN Flashes 5 Hz red » Overload 24 V voltage output

LED Signal Color

Function

Yellow

Off » Digital input 2 is not connected or no mobile unit detected On yellow » Digital input 2 is connected

Function

LED Signal Color

Yellow

Off » Digital input is not connected or no mobile unit detected

Function

On » Digital input is connected Flashes 2 Hz » Overload datavalid Flashes 5 Hz » Overload digital out

34 SMW-electronics