LPS 4.0 Linear Position Sensor System High-precision inductive linear position sensorsystem
Standard connection M12 x 1(5 Pole)
Common communication interfaces: ■ IO-Link ■ Analog signal (0 -10 V/4 -20 mA)
Status displays LEDs Operation and Target detection
Inductive position measurement by target / encoder unit
Sensor
Housing plastic Protection class IP 67/69 K
operating distance
Target/ encoder unit
Required dimensions: LPS 4.0 48/80/120 TARGET / ENCODER UNIT DESIGN
Dimensions
Remark
A = Required distance (light and parallel) between measuring surface and the operating ring
Operating distance A = 1.0 mm ± 0.25
Width B = 19 mm
B = Required width of the operating cam or operating ring
Angle α = 6°
α = Angle min. 6°
Ring
Cam
α
A
B
B
α
Example:Target / encoder unit (cam geometry)
Example:Target / encoder unit (ring geometry)
42 SMW-electronics