2024 Product Catalog

ELECTRICAL INFORMATION

BHP CONVERSION & STEAM FLOW REQUIREMENTS

BHP CONVERSION & STEAM FLOW INFORMATION

BHP Conversion

1 BHP = Approximately 33,475 BTU* 1 BHP = Approximately 10 kW

200,000

Boiler Efficiency

Delivered BHP

*Delivered BHP is a function of kW/BTU input and operating efficiency.

Example:

x

=

33,475 BTU

STEAM FLOW REQUIREMENTS FOR DIRECT KETTLES

Fast Boil (30 minutes)

Medium Boil (45 minutes)

Stock Boil (60 minutes)

Capacity 20-Gallon 40-Gallon 60-Gallon 80-Gallon

lbs/hr.

lbs/hr.

lbs/hr.

48 96

32 64 96

24 48 72 96

143 191

127

Medium Boil (50 minutes)

Stock Boil (65 minutes)

Fast Boil (40 minutes)

100-Gallon 125-Gallon 150-Gallon

179 224 269

143 179 215

110 138 165

NOTE: Steam flow rate at 10 psig at the kettle. 1 boiler horsepower = 34.5 lbs of steam per hour. Heat-up time to bring 70ºF water to boiling (212ºF) at sea level.

MAXIMUM FLOW RATE OF DRY STEAM IN POUNDS PER HOUR

½" ¾" 1"

1¼" 1½" 2"

Supply Pressure

5 psig

20 30 40 50 60 70 80

40 60 80

70

140 220 290 360 430 500 570 760

210 320 430 530

380 600 N/A N/A

10 psig 15 psig 20 psig 25 psig 30 psig 35 psig 50 psig

110 150 180 220 250 290 380

100 120 140 160 210

N/A N/A N/A N/A N/A N/A N/A N/A

100

NOTE: Based on 100' of clean iron pipe. Steam loss due to elbows, reductions, heat loss or condensing steam was not considered.

123

See AutoQuotes for prices. Not responsible for typographical/photographical errors.

Made with FlippingBook Publishing Software