ELECTRICAL INFORMATION
BHP CONVERSION & STEAM FLOW REQUIREMENTS
BHP CONVERSION & STEAM FLOW INFORMATION
BHP Conversion
1 BHP = Approximately 33,475 BTU* 1 BHP = Approximately 10 kW
200,000
Boiler Efficiency
Delivered BHP
*Delivered BHP is a function of kW/BTU input and operating efficiency.
Example:
x
=
33,475 BTU
STEAM FLOW REQUIREMENTS FOR DIRECT KETTLES
Fast Boil (30 minutes)
Medium Boil (45 minutes)
Stock Boil (60 minutes)
Capacity 20-Gallon 40-Gallon 60-Gallon 80-Gallon
lbs/hr
lbs/hr
lbs/hr
48 96
32 64 96
24 48 72 96
143 191
127
Medium Boil (50 minutes)
Stock Boil (65 minutes)
Fast Boil (40 minutes)
100-Gallon 125-Gallon 150-Gallon
179 224 269
143 179 215
110 138 165
Steam flow rate at 10 psig at the kettle. 1 boiler horsepower = 34.5 lbs of steam per hour. Heat-up time to bring 70ºF water to boiling (212ºF) at sea level.
MAXIMUM FLOW RATE OF DRY STEAM IN POUNDS PER HOUR
½" ¾" 1"
1¼" 1½" 2"
Supply Pressure
5 psig
20 30 40 50 60 70 80
40 60 80
70
140 220 290 360 430 500 570 760
210 320 430 530
380 600 N/A N/A
10 psig 15 psig 20 psig 25 psig 30 psig 35 psig 50 psig
110 150 180 220 250 290 380
100 120 140 160 210
N/A N/A N/A N/A N/A N/A N/A N/A
100
Based on 100' of clean iron pipe. Steam loss due to elbows, reductions, heat loss or condensing steam was not considered.
123
See AutoQuotes for prices. Not responsible for typographical/photographical errors.