ELECTRICAL INFORMATION
VC & SG SERIES | An Improved Full Line to Meet Every Convection Oven Need ELECTRICAL / PLUG INFORMATION
Accessory Code
Application
Cable–SOOW, 90ºC GA/#
Plug PN
Plug Configuration
G
CORDPLG 3PAN1P
45A, 208-240V, 1 Phase, right angle plug
8/3
HBL9462C
X
Z
W
G
CORDPLG 3PAN3P
40A, 208-240V, 3 Phase, right angle plug
8/4
HBL8462C
X
Z
Y
G
CORDPLG 5PAN3P
55A, 208-240V, 3 Phase, right angle plug
6/4
HBL8462C
X
Z
Y
X
CORDPLG 5P480
30A, 480V, 3 Phase, straight plug
8/4
HBL2731
G
Y
Z
BHP CONVERSION & STEAM FLOW INFORMATION
BHP Conversion
1 BHP = Approximately 33,475 BTU* 1 BHP = Approximately 10 kW
200,000
Boiler Efficiency
Delivered BHP
*Delivered BHP is a function of kW/BTU input and operating efficiency.
Example:
x
=
33,475 BTU
Steam Flow Requirements for Direct Kettles
Maximum Flow Rate of Dry Steam in Pounds per Hour
Supply Pressure
Fast Boil (30 minutes)
Medium Boil (45 minutes)
Stock Boil (60 minutes)
½" ¾" 1" 1¼" 1½" 2"
5 psig 20 40 70 140 210 380 10 psig 30 60 110 220 320 600 15 psig 40 80 150 290 430 N/A 20 psig 50 100 180 360 530 N/A 25 psig 60 120 220 430 N/A N/A 30 psig 70 140 250 500 N/A N/A 35 psig 80 160 290 570 N/A N/A 50 psig 100 210 380 760 N/A N/A NOTE: Based on 100' of clean iron pipe. Steam loss due to elbows, reductions, heat loss or condensing steam was not considered.
Capacity 20-Gallon 40-Gallon 60-Gallon 80-Gallon
lbs/hr
lbs/hr
lbs/hr
48 96
32 64 96
24 48 72 96
143 191
127
Medium Boil (50 minutes)
Stock Boil (65 minutes)
Fast Boil (40 minutes)
100-Gallon 125-Gallon 150-Gallon
179 224 269
143 179 215
110 138 165
NOTE: Steam flow rate at 10 psig at the kettle. 1 boiler horsepower = 34.5 lbs of steam per hour. Heat-up time to bring 70ºF water to boiling (212ºF) at sea level.
124
vulcanequipment.com | 800-814-2028
Made with FlippingBook Publishing Software