Boulder Historic Places Plan

Structural Condition Definitions

This structural condition assessment makes use of terms concerning the condition of building components which are defined as follows:

Good - A structural element, component or system is considered in good condition when it is undamaged, structurally sound or functionally operational, and performing as intended. No specific repairs are required, and only minor or routine maintenance is needed. Fair - An element, component or system is considered in fair condition when there are signs of wear or deterioration, such as freeze-thaw deterioration, corrosion, or wood decay exceeding expectations based on the age and use of the element, that may be reducing the structural capacity of the member. Replacement or repair of the element may be required. Poor - An element, component, or system is considered in poor condition when it no longer performs its intended structural purpose. Deterioration or damage reduced the load carrying capacity of the element and simple repairs cannot be justified or are not expected to be effective. The element may show signs of imminent failure. Major repair or replacement will be required.

Note: Condition ratings reported are based upon visual observations only. No material testing or exploratory observations have been made. Further investigation could result in modification to condition ratings.

Table 1-2: Condition Assessment of The Arbor

Primary Features

Description

Condition

Foundation Roof Framing

Likely rubble stone masonry below grade

Good Good Good Good Good

Painted timber beams

Walls Floor

Stone piers

Concrete sidewalk

Lateral Force Resisting System Additional Building Systems Irrigation

Log structure and masonry piers

(Backflow preventer, spray heads, etc.) Small lights obscured by timbers

Not Assessed Not Assessed

Electrical

Table 1-3: Condition Assessment of Shelter House

Primary Features

Description

Condition

Foundation Roof Framing

Likely rubble masonry

Good Good Good

Wood-framed mansard roof

Walls Floor

Masonry

Concrete slab on grade

Fair

Lateral Force Resisting System Additional Building Systems Irrigation

Wood roof diaphragm, masonry walls and buttresses

Good

(Backflow preventer, spray heads, etc.)

Not Assessed Not Assessed

Electrical

Lighting

7-25