Structural Condition Definitions
This structural condition assessment makes use of terms concerning the condition of building components which are defined as follows:
Good - A structural element, component or system is considered in good condition when it is undamaged, structurally sound or functionally operational, and performing as intended. No specific repairs are required, and only minor or routine maintenance is needed. Fair - An element, component or system is considered in fair condition when there are signs of wear or deterioration, such as freeze-thaw deterioration, corrosion, or wood decay exceeding expectations based on the age and use of the element, that may be reducing the structural capacity of the member. Replacement or repair of the element may be required. Poor - An element, component, or system is considered in poor condition when it no longer performs its intended structural purpose. Deterioration or damage reduced the load carrying capacity of the element and simple repairs cannot be justified or are not expected to be effective. The element may show signs of imminent failure. Major repair or replacement will be required.
Note: Condition ratings reported are based upon visual observations only. No material testing or exploratory observations have been made. Further investigation could result in modification to condition ratings.
Table 1-2: Condition Assessment of The Arbor
Primary Features
Description
Condition
Foundation Roof Framing
Likely rubble stone masonry below grade
Good Good Good Good Good
Painted timber beams
Walls Floor
Stone piers
Concrete sidewalk
Lateral Force Resisting System Additional Building Systems Irrigation
Log structure and masonry piers
(Backflow preventer, spray heads, etc.) Small lights obscured by timbers
Not Assessed Not Assessed
Electrical
Table 1-3: Condition Assessment of Shelter House
Primary Features
Description
Condition
Foundation Roof Framing
Likely rubble masonry
Good Good Good
Wood-framed mansard roof
Walls Floor
Masonry
Concrete slab on grade
Fair
Lateral Force Resisting System Additional Building Systems Irrigation
Wood roof diaphragm, masonry walls and buttresses
Good
(Backflow preventer, spray heads, etc.)
Not Assessed Not Assessed
Electrical
Lighting
7-25